Mm-Wave power meter 高靈敏度毫米波功率計(jì)
參考價(jià) | ¥ 10000 |
訂貨量 | ≥1 件 |
- 公司名稱 上海屹持光電技術(shù)有限公司
- 品牌 其他品牌
- 型號 Mm-Wave power meter
- 產(chǎn)地
- 廠商性質(zhì) 代理商
- 更新時(shí)間 2024/9/2 16:28:20
- 訪問次數(shù) 693
聯(lián)系方式:馬先生15618996225 查看聯(lián)系方式
聯(lián)系我們時(shí)請說明是化工儀器網(wǎng)上看到的信息,謝謝!
產(chǎn)地類別 | 進(jìn)口 | 應(yīng)用領(lǐng)域 | 農(nóng)業(yè),電子,汽車,電氣 |
---|
高靈敏度毫米波功率計(jì)Features | |
|
|
高靈敏度毫米波功率計(jì)Applications | |
| |
Description | |
The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz. DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor. Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research. ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay. Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse. Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available. Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels. Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors. Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time. |
DPM-XX Key Features and Specifications
- Display readings: milliWatts, microWatts or dBm
- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)
- Frequency Range: 10 MHz to 220 GHz
- Min. measured Power: 0.1 microWatt (depending on frequency band)
- Dynamic Measurement Range: 55dB max. (depending on frequency band)
- Frequency step: 10 MHz
- SCPI or ELVA’s command protocol
- RS-232, GPIB interface
- Calibration accuracy ±0.04 dB (log) or ±1%
- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory
- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness.
Model Number | DPM-C | DPM -28 | DPM -22 | DPM -19 | DPM -15 | DPM -12 | DPM -10 | DPM -08 | DPM -06 | DPM -05 |
Frequency Band | Ka | Q | U | V | E | W | F | D | G | |
Frequency Range, GHz | 0.01-26.5 | 14757 | 33-50 | 40-60 | 50-75 | 60-90 | 75-110 | 90-140 | 110-170 | 140-220 |
Input Waveguide/Impedance | 50 Ohm, Coaxial | WR-28 | WR-22 | WR-19 | WR-15 | WR-12 | WR-10 | WR-08 | WR-06 | WR-05 |
Wavequide Flange/Connector | SMA, male | UG-599/U | UG-383/U | UG-383/U-M | UG-385/U | UG-387/U | UG-387/U-M | UG-387/U-M | UG-387/U-M | UG-387/U-M |
Dynamic Range, dB (max) | 50 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 50 | 40 |
Min Measured Power Level, dBm | -33 | -43 | -43 | -43 | -43 | -43 | -40 | -40 | -35 | -25 |
Measurement Rate (default), times per sec | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
VSWR (power sensor) | 1.2:1 | 1.3:1 | 1.3:1 | 1.3:1 | 1.3:1 | 1.4:1 | 1.4:1 | 1.4:1 | 1.4:1 | 1.4:1 |
Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).