實(shí)驗(yàn)?zāi)康?/span>:
評(píng)價(jià)組件在潮濕工作條件下的絕緣性能,驗(yàn)證雨、霧、露水或溶雪的濕氣不能進(jìn)入組件內(nèi)部電路的工作部分,如果濕氣進(jìn)入可能會(huì)引起腐蝕、漏電或安全事故。
實(shí)驗(yàn)裝置
應(yīng)滿(mǎn)足下列要求:
— 對(duì)于面積小于0.1m2的組件絕緣電阻不小于400MΩ。
— 對(duì)于面積大于0.1m2的組件,測(cè)試絕緣電阻乘以組件面積應(yīng)不小于40MΩ·m2。
BR-PV-WLC Wet Leakage Current Tester with Spray System
Implementation of standards:
IEC 61215:2005 & Ed.3, IEC 61646:2008, IEC 61730-2:2004, UL 1703:2008, VDE 0126-5:2008, VDE 0126-3:2009...
System composition:
Basic framework: Insulating water slot air-conditioning (or constant temperature circulating cistern) detergent conductivity detector surface tension determine instrument spray frame program-controlled insulation voltage tester with Light-Screen safety protection system
Insulation voltage test explains:
IEC 61215/61646/61730, were not given insulation voltage test pass/fail discriminant basis, we quoted UL 1703 "Dielectric Withstand Test" by - as Test discriminant basis, namely: Compression test stage no more than 0.05 mA leakage current. In addition, the program, should not be greater than pressor 500V/s, module belong to capacitive load, we find that moment caused by leakage current charging electric current exceeds.
The insulation and spacings between live parts and accessible conductive parts and between live parts and exposed nonconductivesur faces shall withstand the application of a DC test voltage equal to two times the system voltage plus 1000V without the leakage current between these two points exceeding 50μA DC. The voltage is to be applied in both polarities.
a) 一個(gè)淺槽或容器,其尺寸應(yīng)足夠大到能將組件及邊框水平放入其中的溶液,有符合以下要求的水或溶液
電阻率: 不大于 3500Ω·cm
表面張力:不大于 3Nm-2
溫度: 22℃±3℃
溶液深度應(yīng)有效覆蓋所有表面,不要泡到?jīng)]有為浸泡而設(shè)計(jì)的引線(xiàn)盒入口
b) 有相同溶液的噴淋裝置。
c) 可提供500V或組件系統(tǒng)電壓的較大值 、有電流限制的直流電源。
d) 測(cè)量絕緣電阻的設(shè)備。