官方微信|手機版

產品展廳

產品求購企業(yè)資訊會展

發(fā)布詢價單
日立分析儀器(上海)有限公司

化工儀器網(wǎng)>產品展廳>分析儀器>光譜>原子吸收光譜(AAS)>Z -2000 Atomic Absorption Spectrophotometer

分享
舉報 評價

Z -2000 Atomic Absorption Spectrophotometer

具體成交價以合同協(xié)議為準

聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!


Welcome To Our Company 
  Founded in 1998 , we are a well established and professional supplier of instruments and equipments.

We enjoy good relations with excellent partners in North America ,European Union and Japan .Our principal products include: HTA of Italy, Z-nose of U.S.A, and TEKNOKROMA of Spain and so on.

In the field of chemical analysis ,especially in chromatography, we have sufficient supplies of instruments which are readily available. We ensure the quality of every instrument sold by us, in the meantime, offer satisfactory customer service.

In case of any problem with the instrument, we guarantee a response in 24 hours during workday.

With commitment to credit, we have obtained a large share of Chinese market ,at the same time, won the support and trust from our clients.

Dedicated to the mission of helping our customers spend money in a wiser way and utilize instrument more efficiently, we will unswervingly continue along the path of pushing Chinese instrumental industry to conform to international standards..
 

Chromatography; Spectrophotometer; Titrator; Lab Equipment

features
1. excellent sensitivity using zeeman method and dual detectorthe new optical system and the improved graphitefurnace power supply circuit ensure high sensitivitiesusing an ordinary hollow cathode lamp, the z-2000 series spectrophotometer is capable of analyzingas, se and sb in tap water and environmentalwater, which previously have only been measurable using an edl high-intensity lamp in a conventional graphite furnace analyses. this shows how noisecan be reduced significantly to ensure high sensitivity 2. running cost can be saved by short startup time speedy and stable analysis is ensured by an ideal double-beam photometry in which the polarized zeeman method is adopted for both flame burner and graphite furnace. for example, the baseline usually takes 10 to 25 minutes to stabilize in analysis of pb, an, etc. such a stabilization time is unnecessary for the polarized zeeman method. 3. the baseline is not shifted even with introduction of organic solvent
4. background correction effective for any analyte elements background correction can be carried out over the entire wavelength range using light from the hollow cathode lamp for measurement. 5. flame analyses and graphite furnace analyses can be done without replacing the atomizeratomizer se-lection can be made simply through the software. it is not necessary to replace the atomizer unit nor adjust the optical axis.6. analytical conditions are set up automaticallythe large-turret lamp holder can accommodate up to eight hollow cathode lamps. the lamp position setting, fine adjustment and lamp current se-lection are performed automatically for the element for interest.
您可能感興趣的產品
我要加入


化工儀器網(wǎng)

采購商登錄
記住賬號    找回密碼
沒有賬號?免費注冊

提示

×

*您想獲取產品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息:

溫馨提示

該企業(yè)已關閉在線交流功能