| | | |
| | | Safety control unit module | | SB4 Module 4CG | | | | | | | | | | Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Micro-Controller controls, Operating mode can be selected by means of DIP switches, Number of channels: 4 | | | | | |
| | | Safety control unit module | | SB4 Module 4CP/165 | | | | | | | | | | Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Micro-Controller controls, Operating mode can be selected by means of DIP switches, Number of channels: 4 | | | | | |
| | | Safety control unit module | | SB4 Module 4XG/165 | | | | | | | | | | Sensor module, 4 sensor channels, Micro-Controller controls, Operating mode can be selected by means of DIP switches, Connection of a number of separate de-energising circuits, Number of channels: 4 | | | | | |
| | | Safety control unit | | SC2-2 24VDC | | | | | | | | | | Evaluation device for safety thru-beam sensors SL12 and SL29, Test input (Type 2 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Number of channels: 2 | | | | | |
| | | Safety light grid with integrated control unit | | SLC-3/133 | | | | | | | | | | ATEX-approval for zone 2 and zone 22, Sensing range up to 20 m, Beam spacing 400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Safety outputs OSSD, external status displays OSSD, Effective detection range: 0.2 ... 20 m, Connection: M20 cable gland , Cable diameter ∅5.5 ... 13 mm , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Number of beams: 3, Beam spacing: 400 mm | | | | | |
| | | Safety light grid with integrated control unit | | SLPC10-4 | | | | | | | | | | Sensing range up to 10 m, 4-radial design, Beam spacing 300 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Effective detection range: 0.2 ... 10 m, Connection: M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitter, Number of beams: 4, Beam spacing: 300 mm, Operating mode: Start/restart disable, relay monitor,, Safety output: 2 separated fail safe semiconductor outputs | | | | | |
| | | Safety light grid with integrated control unit | | SLPC10-4/31 | | | | | | | | | | Sensing range up to 10 m, 4-radial design, Beam spacing 300 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Effective detection range: 0.2 ... 10 m, Connection: M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitter, Number of beams: 4, Beam spacing: 300 mm, Operating mode: Start/restart disable, relay monitor,, Safety output: 2 relay outputs, force-guided NO-contact | | | | | |
| | | Safety light grid with integrated control unit | | SLPC8-2/31 | | | | | | | | | | Sensing range up to 8 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Minimum wiring expense due to transceiver with passive mirror column, Effective detection range: 0.2 ... 8 m, Connection: M16 cable gland , terminal compartment with cage-terminals, Number of beams: 2, Beam spacing: 500 mm, Operating mode: Start/restart disable, relay monitor,, Safety output: 2 relay outputs, force-guided NO-contact | | | | | |
| | | Safety light grid with integrated control unit | | SLPCM10-2-L/31 | | | | | | | | | | Sensing range up to 10 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Effective detection range: 0.2 ... 10 m, Connection: M16 cable gland , terminal compartment with cage terminals, M12 connector for transmitters, muting lamp, etc., muting sensors, lamp socket for muting lamp, etc., Number of beams: 2, Beam spacing: 500 mm, Operating mode: Start/restart disable, relay monitor, muting operating modes | | | | | |
| | | Evaluation unit | | SLVA-4Kplus 115VAC-RI | | | | | | | | | | Self-monitoring (type 4 according to IEC/EN 61496-1), Evaluation device for safety thru-beam sensors SLA, for safety light grids SLP and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Number of channels: 4 | | | | | |