Themal Shock Test Chamber TSA Series About Higher performance The TSA Series aims at fulfilling high-level requirements for thermal shock testing. The advanced model achieves 1000-cycle consecutive tests without defrosting (option), and offers reduced temperature recovery time, heat up and pull down time. Features an eco operation mode for more energy savings. | | Reduced power consumption With the eco operation mode, operating time is shortened by temporarily suspending temperature pre-conditioning periods. | Reduced test duration In 2 zone test, the TSA achieves 1000-cycle consecutive test (500-hour) without activating defrost operation usually required. This allows dramatic reduction of the overall test time. | | Specifications Model | Temperature range | Inside / Outside dimensions (mm) | TSA-71H | High temp. exposure: +60 to +200°C (+140 to +392°F) Low temp. exposure: -70 to 0°C (-94 to +32°F) | W410×H460×D370 / W1310×H1900×D1670 | TSA-71S | TSA-101S | W650×H460×D370 / W1550×H1900×D1370 | TSA-201S | W650×H460×D670 / W1550×H1900×D1670 | TSA-41L | High temp. exposure: +60 to +200°C (+140 to +392°F) Low temp. exposure: -65 to 0°C (-85 to +32°F) | W240×H460×D370 / W1140×H1900×D1170 | TSA-71L | W410×H460×D370 / W1310×H1900×D1370 | TSA-101L | W650×H460×D670 / W1550×H1900×D1370 | TSA-301L | W970×H460×D670 / W1870×H1900×D1670 | | | Features - Short temperature recovery time
The maximum temperature recovery time at upstream air for 2 zone test (+150°C and -65°C) and 3 zone test is only 5 min. (10 min. for TSA-201S and TSA-301L) - Great uniformity
Horizontal air flow system offers excellent specimen temperature uniformity. - Efficiency thanks to specimen temperature control (option)
Thanks to this feature, the equipment achieves set temperature attainment with rapidity and accuracy. - STT function (option)
Thanks to the specimen temperature monitor with trigger, exposure time starts only when the specimen has reached the set temperature, leading to more precise test results. - User-friendly controller
The LCD touch-screen controller allows easy check of the test patterns, temperatures settings, test cycles and graph displays. - Reduced load current
- Reduced operating noise
Energy-saving - Reduced operating time
The eco operation mode reduces the operating time by temporarily suspending following periods: - Pre-cooling of the low temperature chamber during high temp. exposure, - Preheating of the high temperature chamber during low temp. exposure.Thanks to the eco operation mode, power consumption is dramatically reduced especially for long exposure time, and tests requiring many cycles. (except TSA-41L) - Unique chamber structure
(Patent No. 3514735) ESPEC’s unique design enables 1000-cycle (500-hour) without defrosting in 2 zone test. The structure prevents outside air to penetrate, which is usually causing frost. Constant environmental conditions are maintained, thus expanding the defrost-free operation range. *Models supporting defrost-free operation TSA-71H-W: 1000 cycles (500 hours) TSA-201S-W: 500 cycles (500 hours) Continuous operation is not supported for some test conditions. | - Cumulative power consumption during eco operation
- 1000-cycle test time comparison (option)
| Options - Defrost-free operation
- Specimen temperature control
- Specimen temperature
monitor with trigger function - Paperless recorder
- Temperature recorder (digital)
- Temperature recorder for
future installation - Recorder terminal
- Thermocouple
- Exposure signal output
- Additional overheat protector
- External alarm terminal
- Emergency stop switch
- Total cycle counter
| - Auxiliary cooling injector (LCO2)
- Auxiliary cooling injector (LN2)
- Built-in air compressor
- Automatic door
- Additional cable port
- Cable port rubber plug
- Casters
- Specimen basket / shelf bracket
- Heavy-duty shelves
- Chamber dew tray
- Fixture for securing body
- Exhaust duct
- Color specification
- Communication functions
- Power cable
| |