產(chǎn)品簡介
詳細介紹
EPCOS EMC穿心電容器
Rated voltage VR: 110 V AC to 440 V AC
Rated current IR: 16 A to 200 A
Rated capacitance CR: 0.0025 µF to 4.7 µF
Construction
Building-block system
MKP/MKT technology (dry, self-healing)
Dielectric: polypropylene or polyester, metallized
Metal case, polyurethane potting (UL 94 V-0)
For central screw fixing
Features
Compact dimensions
High insertion loss
Easy to install
High contact reliability thanks to central screw fixing
Design complies with IEC 60384-14
UL 60384-14 pending
Typical applications
Broadband interference suppression
for AC/DC supply lines, e. g. in
shielded rooms
ephone exchanges, base stations
electrical machines and systems
power supplies
Terminals
Threaded studs
Axial leads
Cautions and warnings
Please read all safety and warning notes carefully before installing the EMC filter and putting it
into operation (see ). The same applies to the warning signs on the filter. Please ensure that
the signs are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the
appropriate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The EMC filters may be used only for their intended application within the specified values in lowvoltage
networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warning
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous
voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
The protective earth connections shall be the first to be made when the EMC filter is installed
and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter or filter, such as with circuits able to cause resonances,
impermissible voltages at higher frequencies etc. can lead to bodily injury and death as
well as cause substantial material damages (e.g. destruction of the filter housing).
EMC filters and filters must be protected in the application against impermissible exceeding of
the rated currents by overcurrent protective circuitry.