產(chǎn)品展廳收藏該商鋪

您好 登錄 注冊

當前位置:
世聯(lián)博研(北京)科技有限公司>技術(shù)文章>cellscale biotester 平面雙軸拉伸試驗機文獻,

技術(shù)文章

cellscale biotester 平面雙軸拉伸試驗機文獻,

閱讀:906          發(fā)布時間:2019-12-20
所用科研工具發(fā)表年份論文標題作者
BioTester2019An Investigation Of Regional Variations In The Biaxial Mechanical Properties And Stress Relaxation Behaviors Of Porcine Atrioventricular Heart Valve LeafletsD. Laurence, C. Ross, S. Jett, C. Johns, A. Echols, R. Baumwart, R. Towner, J. Liao, P. Bajona, Y. Wu, C. H. Lee
BioTester2019Strain Effects On Collagen Proteolysis In Heart Valve TissuesK. Barbour, H. Y. S. Huang
BioTester2019Comparison Of Biomechanical Properties And Microstructure Of Trabeculae Carneae, Papillary Muscles, And Myocardium In The Human HeartF. Fatemifar, M. D. Feldman, M. Oglesby, H. C. Han
BioTester2019Rate-Dependency Of The Mechanical Behavior Of Semilunar Heart Valves Under Biaxial DeformationA. Anssari-Benam, Y-T. Tseng, A. Bucchi
BioTester2019An Investigation Of Layer-Specific Tissue Biomechanics Of Porcine Atrioventricular Valve Anterior LeafletsK. Kramer, C. Ross, A. Babu, Y. Wu, R. Towner, A. Mir, H. M. Burkhart, G. A. Holzapfel, C. H. Lee
BioTester2019The Degradation And Performance Of Electrospun Supramolecular Vascular Scaffolds Examined Upon In Vitro Enzymatic ExposureE. E. van Haaften, R. Duijvelshoff, B. D. Ippela, S. H. M. Sontjens, M. H. C. J. van Houtem, H. M. Janssen, A. I. P. M. Smits, N. A. Kurniawan, P. Y. W. Dankers, C. V. C. Bouten
BioTester2019Mechanical Damage Characterization In Human Femoropopliteal Arteries Of Different AgesE. Anttila, D. Balzani, A. Desyatova, P. Deegan, J. MacTaggart, A. Kamenskiy
BioTester2019Cyclic Strain Affects Macrophage Cytokine Secretion And Extracellular Matrix Turnover In Electrospun ScaffoldsV. Bonito, B. J. deKort, C. V. C. Bouten, A. I. P. M. Smits
BioTester2019Image-Based Analysis Of Uniaxial Ring Test For Mechanical Characterization Of Soft Materials And Biological TissuesE. E. van Haaften, M. C. van Turnhout, N. A. Kurniawan
BioTester2019Mechanical Properties of Autologous Pericardium Change with Fixation Time: Implications for Valve ReconstructionS. C. Hofferberth, C. W. Baird, D. M. Hoganson, L. G. Quinonez, S. M. Emani, P. J. Del Nido, P. E. Hammer
BioTester2019Tissue Level Mechanical Properties and Extracellular Matrix Investigation of the Bovine Jugular Venous Valve TissueA. A. Benson, H-Y. S. Huang
BioTester2019Regional Biaxial Mechanical Data of the Mitral and Tricuspid Valve Anterior LeafletsD. Laurence, C. Ross, S. Jett, C. Johns, A. Echols, R. Baumwart, R. Towner, J. Liao, P. Bajona, Y. Wu, C. H. Lee
BioTester2019Mechanics of the Tricuspid Valve-From Clinical Diagnosis/Treatment, In-Vivo and In-Vitro Investigations, to Patient-Specific Biomechanical Modeling.C. H. Lee, D. Laurence, C. Ross, K. Kramer, A. Babu, E. Johnson, M. C. Hsu, A. Aggarwal, A. Mir, H. Burkhart, R. Towner, B. Baumwart, Y. Wu
BioTester2019An Investigation of the Glycosaminoglycan Contribution to Biaxial Mechanical Behaviours of Porcine Atrioventricular Heart Valve LeafletsC. Ross, D. Laurence, Y. Wu, J. Richardson, A. Babu, L. Evans, E. Beyer, R. Childers, Y. Wu, R. Towner, K. M. Fung, A. Mir, H. Burkhart, G. A. Holzapfel, C. H. Lee
BioTester2019Macrophage-Driven Biomaterial Degradation Depends on Scaffold MicroarchitectureT. Wissing, V. Bonito, E. Haaften, M. Doeselaar, M. Brugmans, H. Janssen, C. Bouten, A. Smits
BioTester2019The Effect of Axial Torsion on the Mechanical Properties of the Annulus FibrosusM. Harvey-Burgess, D. Gregory
BioTester2019Integration of Polarized Spatial Frequency Domain Imaging (pSFDI) with a Biaxial Mechanical Testing System for Dynamic Quantification of Collagen Architecture in Soft Collagenous TissuesS. Jett, L. Hudson, R. Baumwart, B. Bohnstedt, A. Mir, H. Burkhart, G. Holzapfel, C-H. Lee, Y. Wu
BioTester2019An Integrated Opto-Mechanical System for Quantification of Dynamic Microstructure and Mechanics of Heart Valve TissuesS. Jett, Z. Schuermann, A. Mir, H. Burkhart, C-H. Lee
BioTester2019Effects of longitudinal pre-stretch on the mechanics of human aorta before and after thoracic endovascular aortic repair (TEVAR) in trauma patientsA. Desyatova, J. MacTaggart, A. Kamenskiy
BioTester2019Human in vitro model of material-driven vascular regeneration reveals how cyclic stretch and shear stress differentially modulate inflammation and tissue formationE. Haaften, T. Wissing, N. Kurniawan, A. Smits, C. Bouten
BioTester2019Some Effects of Different Constitutive Laws on FSI Simulation for the Mitral ValveL. Cai, Y. Wang, H. Gao, X. Ma, G. Zhu, R. Zhang, X. Shen, X. Luo
BioTester2019Biomechanical Restoration Potential of Pentagalloyl Glucose after Arterial Extracellular Matrix DegenerationS. Patnaik, S. Piskin, N. Pillalamarri, G. Romero, G. Escobar, E. Sprague, E. Finol
BioTester2019An investigation of the effect of freezing storage on the biaxial mechanical properties of excised porcine tricuspid valve anterior leafletsG. Duginski, C. Ross, D. Laurence, C. Johns, C-H. Lee
BioTester2019A Detailed Mechanical and Microstructural Analysis of the Ovine Tricuspid Valve LeafletsW. Meador, M. Mathur, T. Jazwiec, M. Malinowski, M. Bersi, T. Timek, M. Rausch
BioTester2019The regional-dependent biaxial behavior of young and aged mouse skin: A detailed histomechanical characterization, residual strain analysis, and constitutive modelW. Meador, G. Sugerman, H. Story, A. Seifert, M. Bersi, A. Tepole, M. Rausch
BioTester2018Biaxial Mechanical Behavior Of Bovine Saphenous Venous Valve LeafletsJ. Lu, H-Y S. Huang
BioTester2018Prevalence Of Calcification In Human Femoropopliteal Arteries And Its Association With Demographics, Risk Factors, And Arterial StiffnessA. Kamenskiy, W. Poulson, S. Sim, A. Reilly, J. Luo, J. MacTaggart
BioTester2018Comparison Of Corneal Biomechanics After Myopic Small-Incision Lenticule Extraction Compared To Lasik: An Ex Vivo StudyA.J. Kanellopoulos
BioTester2018Dehiscence Of Patch Augmentation Of A Left-Sided Atrioventricular Valve Related To Strenuous Isometric Exercise: Case Report And Failure AnalysisP.E. Hammer, C.W. Baird, P.J. del Nido, G.R. Marx
BioTester2018Puncturing Of Lyophilized Tissue Engineered Vascular Matrices Enhances The Efficiency Of Their RecellularizationA.A. Ksiazek, L. Frese, P.E. Dijkman, B. Sanders, S. E. Motta, B. Weber, S.P. Hoerstrup
BioTester2018Biomechanical Evaluation Of A Personalized External Aortic Root Support Applied In The Ross ProcedureJ. Vastmans, H. Fehervary, P. Verbrugghe, T. Verbelen, E. Vanderveken, J. Vander Sloten, T. Treasure, F. Rega, N. Famaey
BioTester2018Polydopamine As Sizing On Carbon Fiber Surfaces For Enhancement Of Epoxy Laminated CompositesW. Han, H-P. Zhang, J. Tavakoli, J. Campbell, Y. Tang
BioTester2018Comparison Of In Vivo Vs. Ex Situ Obtained Material Properties Of Sheep Common Carotid ArteryM. Smoljkic, P. Verbrugghe, M. Larsson, E. Widman, H. Fehervary, J. D'hooge, J. Vander Sloten, N. Famaey
BioTester2018Soy Protein/Cellulose Nanofiber Scaffolds Mimicking Skin Extracellular Matrix For Enhanced Wound HealingS. Ahn, C.O. Chantre, A.R. Gannon, J.U. Lind, P.H. Campbell, T. Grevesse, B.B. O'Conner, K.K. Parker
BioTester2018New Findings Confirm The Viscoelastic Behaviour Of The Inter-Lamellar Matrix Of The Disc Annulus Fibrosus In Radial And Circumferential Directions Of LoadingJ. Tavakoli, J.J. Costi
BioTester20183d Printed, Controlled Release, Tritherapeutic Tablet Matrix For Advanced Anti-Hiv-1 Drug DeliveryM. Siyawamwaya, L.C. du Toit, P. Kumar, Y.E. Choonara, P.P.P.D Kondiah, V. Pillay
BioTester2018Computational Modeling Guides Tissue-Engineered Heart Valve Design For Long-Term In Vivo Performance In A Translational Sheep ModelM.Y. Emmert, B.A. Schmitt, S. Loerakker, B. Sanders, H. Spriestersbach,, E.S. Fioretta, L. Bruder, K. Brakmann, S.E. Motta, V. Lintas, P.E. Dijkman, L. Frese, F. Berger, F.P.T. Baaijens, S.P. Hoerstrup
BioTester2018Pressure-Induced End-Plate Fracture In The Porcine Spine: Is The Annulus Fibrosus Susceptible To Damage?C.R. Snow, M.Harvey-Burgess, B. Laird, S.H.M Brown, D.E. Gregory
BioTester2018Dual Electrospun Supramolecular Polymer Systems For Selective Cell MigrationS.H. Thakker, A. Di Luca, S. Zaccaria, F.P.T Baaijens, C.V.C. Bouten, P.Y.W. Dankers
BioTester2018Regional Mechanical And Biochemical Properties Of The Porcine Cortical MeningesD.R. Walsh, A.M. Ross, S. Malijauskaite, B.D. Flanagan, D.T. Newport, K.D. McGourty, J.J.E. Mulvihill
BioTester2018New Insights Into The Viscoelastic And Failure Mechanical Properties Of The Elastic Fiber Network Of The Inter-Lamellar Matrix In The Annulus Fibrosus Of The DiscJ. Tavakoli, J.J. Costi
BioTester2018Initial Scaffold Thickness Affects The Emergence Of A Geometrical And Mechanical Equilibrium In Engineered Cardiovascular TissuesM.A.J. van Kelle, P.J.A. Oomen, W.J.T. Janssen-van den Broek, R.G.P. Lopata, S. Loerakker, C.V.C. Bouten
BioTester2018Development Of An Improved Parameter Fitting Method For Planar Biaxial Testing Using RakesH. Fehervary, J. Vander Sloten, N. Famaey
BioTester2018The Biomechanics Of The Inter-Lamellar Matrix And The Lamellae During Progression To Lumbar Disc Herniation: Which Is The Weakest Structure?J. Tavakoli, D.B. Amin, B.J.C. Freeman, J.J. Costi
BioTester2018Mechanically Robust Cryogels With Injectability And Bioprinting Supportability For Adipose Tissue EngineeringD. Qi, S. Wu, M.A.Kuss, W.Shi, S. Chung, P.T. Deegan, A. Kamenskiy, Y. He, B. Duan
BioTester2018Biomechanical Characterization Of Human Dura MaterD. DeKegel, J. Vastmans, H. Fehervary, B. Depreitere, J. Vander Sloten, N. Famaey
BioTester20183d Printed, Pva–Paa Hydrogel Loaded-Polycaprolactone Scaffold For The Delivery Of Hydrophilic In-Situ Formed Sodium IndomethacinM. Govender, S. Indermum, P. Kumar, Y.E. Choonara, V. Pillay
BioTester2018A Transverse Isotropic Constitutive Model For The Aortic Valve Tissue Incorporating Rate-Dependency And Fibre Dispersion: Application To Biaxial DeformationA. Anssari-Benam, Y-T. Tseng, A. Bucchi
BioTester2018Decoupling The Effect Of Shear Stress And Stretch On Tissue Growth And Remodeling In A Vascular GraftE.E. van Haaften, et. al.
BioTester2018An Investigation Of The Anisotropic Mechanical Properties And Anatomical Structure Of Porcine Atrioventricular Heart ValvesS. Jett, D. Laurence, R. Kunkel, A. R. Babu, K. Kramer, R. Baumwart, R. Towner, Y. Wu, C-H. Lee
BioTester2018Biaxial Mechanical Data of Porcine Atrioventricular Valve LeafletsS. Jett, D. Laurence, R. Kunkel, A. Babu, K. Kramer, R. Baumwart, R. Towner, Y. Wu, C. H. Lee
BioTester2018Biaxial Mechanical Characterization of Atrioventricular Heart ValvesC. Ross, D. Laurence, Y. Wu, C. H. Lee
BioTester2017Biaxial Experimental And Analytical Characterization Of A Dielectric ElastomerA. Helal, M. Doumit, R. Shaheen
BioTester2017Biaxial Mechanical Properties Of Bovine Jugular Venous Valve Leaflet TissuesH-Y. S. Huang, J. Lu
BioTester2017Comparison Of Femoropopliteal Artery Stents Under Axial And Radial Compression, Axial Tension, Bending, And Torsion DeformationsK. Maleckis, P. Deegan, W. Poulson, C. Sievers, A. Desyatova, J. MacTaggart, A. Kamenskiy
BioTester2017Constitutive Modeling Of Human Femoropopliteal Artery Biaxial Stiffening Due To Aging And DiabetesA. Desyatova, J. MacTaggart, A. Kamenskiy
BioTester2017Constitutive Modeling Of Jugular Vein-Derived Venous Valve Leaflet TissuesN. Kaul, H-Y. S. Huang
BioTester2017Design And Characterization Of A Hyperelastic Tubular Soft CompositeR. Shaheen, M. Doumit, A. Helal
BioTester2017In Situ Heart Valve Tissue Engineering Using A Bioresorbable Elastomeric Implant – From Material Design To 12 Months Follow-Up In SheepJ. Kluin, H. Talacua, A.I.P.M. Smits, M. Y. Emmert, M.C.P. Brugmans, E.S. Fioretta, P.E. Dijkman, S.H.M. Sontjens, R.Duijvelshoff, S. Dekker, M.W.J.T. Janssen-van den Broek, V. Lintas, A. Vink, S.P. Hoerstrup, H.M. Janssen, P.Y.W. Dankers, F.P.T. Baaijens, C.V.C. Bouten
BioTester2017Jetvalve: Rapid Manufacturing Of Biohybrid Scaffolds For Biomimetic Heart Valve ReplacementA.K. Capulli, M.Y. Emmert, F.S. Pasqualini, D. Kehl, E. Caliskan, J.U. Lind, S. P. Sheehy, S.J. Park, S. Ahn, B. Weber, J.A. Goss, S.P Hoerstrup, K.K. Parker
BioTester2017Limb Flexion-Induced Twist And Associated Intramural Stresses In The Human Femoropopliteal ArteryA. Desyatova, W. Poulson, P. Deegan, C. Lomneth, A. Seas, K. Maleckis, J. MacTaggart, A. Kamenskiy
BioTester2017Mechanically Robust Electrospun Hydrogel Scaffolds Crosslinked Via Supramolecular InteractionsB.B. Mollet, S. Spaans, P.G. Fard, N.A.M. Bax, C.V.C. Bouten, P.Y.W. Dankers
BioTester2017Nondestructive Mechanical Characterization Of Developing Biological Tissues Using Inflation TestingP.J.A. Oomen, M.A.J. van Kelle, C.W.J. Oomens, C.V.C. Bouten, S. Loerakker
BioTester2017On The Influence Of Wall Calcification And Intraluminal Thrombus On Prediction Of Abdominal Aortic Aneurysm RuptureH.E. Barrett, E.M. Cunnane, H. Hidayat, J.M. O'Brien, M.A. Moloney, E.G. Kavanagh, M.T. Walsh
BioTester2017Paraspinal Muscle Passive Stiffness Remodels In Direct Response To Spine Stiffness: A Study Using The Ent1-Deficient MouseK. Gsell, D. Zwambag, D.E. Fournier, C.A. Seguin, S.H.M. Brown
BioTester2017Tensile Behaviour Of Individual Fibre Bundles In The Human Lumbar Anulus FibrosusD.T. Pham, J.G. Shapter, J.J. Costi
BioTester2017Urinary Bladder Versus Gastrointestinal Tissue: A Comparative Study Of Their Biomechanical Properties For Urinary Tract ReconstructionN.F. Davis, J.J.E. Mulvihill, S. Mulay, E.M. Cunnane, D.M. Bolton, M.T. Walsh
BioTester2016A Comparison Between Porcine, Ovine, And Bovine Intervertebral Disc Anatomy And Single Lamella Annulus Fibrosis Tensile PropertiesL.A. Monaco, S.J. DeWitte-Orr, D.E. Gregory
BioTester2016Acute Pergolide Exposure Stiffens Engineered Valve Interstitial Cell Tissues And Reduces Contractility In VitroA.K. Capulli, L.A. MacQueen, B.B. O'Conner, S. Dauth, K.K. Parker
BioTester2016Age-Dependent Changes In Geometry, Tissue Composition And Mechanical Properties Of Fetal To Adult Cryopreserved Human Heart ValvesD. van Geeman, A.L.F. Soares, P.J.M. Oomen, A. Dressen-Mol, M.W.J.T. Janssen-van den Broek, A.J. van den Bogaerdt, J.J.C. Bogers, M-J. T.H. Goumans, F.P.T. Baaijens, C.V.C. Bouten
BioTester2016Are Adipose-Derived Stem Cells C*ted In Human Platelet Lysate Suitable For Heart Valve Tissue EngineeringL. Frese, T. Sasse, B. Sanders, F.P.T. Baaijens, G.M. Beer, S.P. Hoerstrup
BioTester2016Biaxial Quantification Of Deep Layer Transverse Carpal Ligament Elastic Properties By Sex And RegionB. Mathers, A. Agur, M. Oliver, K. Gordon
BioTester2016Biomechanical Characterization Of Ascending Aortic AneurysmsM. Smoljkic, H. Fehervary, P. Van den Bergh, A. Jorge-Penas, L. Kluyskens, S. Dymarkowski, P. Verbrugghe, B. Meuris, J. Vander Sloten, N. Famaey
BioTester2016Biomechanical Properties And Microstructure Of Heart Chambers: A Paired Comparison Study In An Ovine ModelS. Javani, M. Gordon, A.N. Azadani
BioTester2016Characterization Of Three-Dimensional Anisotropic Heart Valve Tissue Mechanical Properties Using Inverse Finite Element AnalysisM. Abbasi, M.S. Barakat, K. Vanhidkhah, A.N. Azadani
BioTester2016Constitutive Description Of Human Femoropopliteal Artery AgingA. Kamenskiy, A. Seas, P. Deegan, W. Poulson, E. Anttila, S. Sim, A. Desyatova, J. MacTaggart
BioTester2016Deposition Of A Hydrophilic Nanocomposite-Based Coating On A Silicone Hydrogel Through A Laser Process To Minimize Uv Exposure And Bacterial ContaminationG. Huang, W. H. Tse, J. Zhang
BioTester2016Improved Geometry Of Decellularized Tissue Engineered Heart Valves To Prevent Leaflet RetractionB. Sanders, S. Loerakker, E.S. Fioretta, D.J.P. Bax, A. Driessen-Mol, S.P. Hoerstrup, F.P.T. Baaijens
BioTester2016Inflation And Bi-Axial Tensile Testing Of Healthy Porcine Carotid ArteriesR.W. Boekhoven, M.F.J. Peters, M.C.M. Rutten, M.R. van Sambeek, F.N. van de Vosse, R.G.P Lopata
BioTester2016Modulation Of Collaen Fiber Orientation By Strain-Controlled Enzymatic DegradationS. Ghazanfari, A. Dressen-Mol, C.V.C. Bouten, F.P.T. Baaijens
BioTester2016Nanocomposited Coatings Produced By Laser-Assisted Process To Prevent Silicone Hydrogels From Protein Fouling And Bacterial ContaminationG. Huang, Y. Chen, J. Zhang
BioTester2016Patient Specific Vascular Benchtop Models For Development And Validation Of Medical Devices For Minimally Invasive ProceduresM. Kvasnytsia, N. Famaey, M. Bohm, E. Verhoelst
BioTester2016Peak Stress In The Annulus Fibrosis Under Cyclic Biaxial Tensile LoadingC.E. Gooyers, J.P. Callaghan
BioTester2016Phototactic Guidance Of A Tissue-Engineered Soft-Robotic RayS-J. Park, M. Gazzola, K.S. Park, S. Park, V. Di Santo, E.L Blevins, J.U. Lind, P.H. Campbell, S. Dauth, K.K. Parker
BioTester2016Planar Biaxial Testing Of Heart Valve Cusp Replacement Biomaterials: Experiments, Theory And Material ConstantsM.R. Labrosse, R. Jafar, J.Ngu, M. Boodhwani
BioTester2016Planar Biaxial Testing Of Soft Biological Tissue Using Rakes: A Critical Analysis Of Protocol And Fitting ProcessH. Fehervary, M. Smoljkic, J.Vander Sloten, N. Famaey
BioTester2016Production Of Synthetic, Para-Aramid And Biopolymer Nanofibers By Immersion Rotary Jet-SpinningG.M. Gonzalez, L.A. MacQueen, J.U. Lind, S.A. Fitzgibbons, C. O. Chantre, I. Huggler, H.M. Golecki, J.A. Goss, K.K. Parker
BioTester2016Quantification Of Coupled Stiffness And Fiber Orientation Remodeling In Hypertensive Rat Right-Ventricular Myocardium Using 3d Ultrasound Speckle Tracking With Biaxial TestingD.W. Park, A. Sebastiani, C.H. Yap, M.A. Simon, K. Kim
BioTester2016The Aging Disc: Using An Ovine Model To Examine Age-Related Differences In The Biomechanical Properties Of The Intralamellar Matrix Of Single LamellaeD.M. Stewart, L.A. Monaco, D.E. Gregory
BioTester2016The Choice Of A Constitutive Formulation For Modeling Limb Flexion-Induced Deformations And Stresses In The Human Femoropopliteal Arteries Of Different AgesA. Desyatova, J. MacTaggart, W. Poulson, P. Deegan, C. Lomneth, A. Sandip, A. Kamenskiy
BioTester2016The Effect Of Local Hydration Environment On The Mechanical Properties And Unloaded Temporal Changes Of Isolated Porcine Annular SamplesK.M. Gruevski, C.E. Gooyers, T. Karakolis, J.P. Callaghan
BioTester2015Adipose Derived Tissue Engineered Heart ValveL. Frese, B. Sanders, G.M. Beer, B. Weber, A. Driessen-Mol, F.P.T. Baaijens, S.P. Hoerstrup
BioTester2015Biaxial Stress Relaxation Of Semilunar Heart Valve Leaflets During Simulated Collagen Catabolism: Effects Of Collagenase Concentration And Equibiaxial Strain StateS. Huang, H.-Y. S. Huang
BioTester2015Building A Better Infarct: Modulation Of Collagen Cross-Linking To Increase Infarct Stiffness And Reduce Left Ventricular Dilation Post-Myocardial InfarctionA.P. Voorhees, K.Y. DeLeon-Pennell, Y. Ma, G. V. Halade, A. Yabluchanskiy, R. Padmanabhan, E. Flynn, C.A. Cates, M.L. Lindsey, H.-C. Han
BioTester2015Corneal Collagen Cross-Linking Combined With Simulation Of Femtosecond Laser-Assisted Refractive Lens Extraction: An Ex Vivo Biomechanical Effect EvaluationA.J. Kanellopoulos, M.A. Kontos, S. Chen, G. Asimellis
BioTester2015Development Of Non-Cell Adhesive Vascular Grafts Using Supramolecular Building BlocksG. C. van Almen, H. Talacua, B.D. Ippel, B.B. Mollet, M. Ramaekers, M. Simonet, A.I.P.M. Smits, C.V.C. Bouten, J. Kluin, P.Y.W. Dankers
BioTester2015High-Irradiance Cxl Combined With Myopic Lasik: Flap And Residual Stroma Biomechanical Properties Studied Ex-VivoA.J. Kanellopoulos, G. Asimellis, B.Salvador-Culla, J. Chodosh, J.B. Ciolino
BioTester2015Leaflet Stress And Strain Distributions Following Incomplete Transcatheter Aortic Valve ExpansionM. Abbasi, A.N. Azadani
BioTester2015Methods For Using 3-D Ultrasound Speckle Tracking In Biaxial Mechanical Testing Of Biological Tissue SamplesC.H. Yap, D.W. Park, D. Dutta, M. Simon, K. Kim
BioTester2015Nanocomposite Silicone Hydrogels With A Laser-Assisted Surface Modification For Inhibiting The Growth Of Baterial BiofilmP. Yin, G.B. Huang, W.H. Tse, Y.G. Bao, J. Denstedt, J. Zhang
BioTester2015Regional And Depth Variability Of Porcine Meniscal Mechanical Properties Through Biaxial TestingA. Kahlon, M.B. Hurtig, K.D. Gordon
BioTester2015Superior Tissue Evolution In Slow Degrading Scaffolds For Valvular Tissue EngineeringM. Brugmans, S. Soekhradj-Soechit, D. van Geemen, M.A.J. Cox, C. Bouten, F.P.T. Baaijens, A. Driessen-Mol
BioTester2015The Biomechanics Of Eyelid Tarsus TissueM.T. Sun, D. Pham, A.J. O'Conner, J. Wood, R. Casson, D. Selva, J.J. Costi
BioTester2014Cardiac Function Of The Naked Mole-Rat: Echophysiological Responses To Working UndergroundK.M. Grimes, A. Voorhees, Y.A. Chiao, H-C. Han, M.L. Lindsey, R. Buffenstein
BioTester2014Directional Biomechanical Properties Of Porcine Skin TissueH-Y. Huang, S. Huang, C.P. Frazier, P.M. Prim, O. Harrysson
BioTester2014Modeling The Impact Of Scaffold Architecture And Mechanical Loading On Collagen Turnover In Engineered Cardiovascular TissuesG. Argento, N. de Jonge, S.H.M. Sontjens, C.W.J. Oomens, C.V.C. Bouten, F.P.T. Baaijens
BioTester2014Should A Native Depth-Dependent Distribution Of Human Meniscus Constitutive Components Be Considered In Fea-Models Of The Knee Joint?J.M. Parraga Quiroga, P. Emmans, W. Wilson, K. Ito, C.C. van Donkelaar
BioTester2014Strain-Dependent Modulation Of Macrophage Polarization Within ScaffoldsV. Ballotta, A. Dressen-Mol, C.V.C. Bouten, F.P.T. Baaijens
BioTester2014Structural And Mechanical Adaptations Of Right Ventrical Free Wall Myocardium To Pressure OverloadM.R. Hill, M.A. Simon, D. Valdez-Jasso, H.C. Champion, M.S. Sacks
BioTester2014The Biaxial Biomechanical Behavior Of Adominal Aortic Aneurysm TissueS.A. O'Leary, D.A. Healey, E.G. Kavanagh, M.T. Walsh, T.M. McGloughling, B.J. Doyle
BioTester2014The Biaxial Mechanical Behaviour Of Abdominal Aortic Aneurysm Intraluminal Thrombus: Classification Of Morphology And The Determination Of Layer And Region Specific PropertiesS.A. O'Leary, E.G. Kavanagh, P.A. Grace, T.M. McGloughlin, B.J. Doyle
BioTester2014The Impact Of Long Term Freezing On The Mechanical Properties Of Porcine Aortic TissueS. O'Leary, B. Doyle, T. McGloughlin
BioTester2014Vascular Elastography: A Validation StudyR.G.P. Lopata, M.F.J. Peters, J. Nijs, C.W. Oomens, M.C.M. Rutten, F.N. van de Vosse
BioTester2013A Nanocomposite Contact Lens For The Delivery Of Hydrophilic Protein DrugsJ. Zhang, R. Bi, W. Hodge, P. Yin, W.H. Tse
BioTester2013Comparison Of Methods Used To Measure The Thickness Of Soft Tissues And Their Influence On The Evaluation Of Tensile StressS.A. O'Leary, B.J. Doyle, T.M. McGloughlin
BioTester2013Corneal Resistance To Shear Force After Uva-Riboflavin Cross-LinkingA.P. Sondergaard, A. Ivarsen, J. Hjortdal
BioTester2013In Vitro Fabrication Of Autologous Living Tissue-Engineered Vascular Grafts Based On Prenatally Harvested Ovine Amniotic Fluid-Derived Stem CellsB. Weber, D. Kehl, U. Bleul, S. Sammut, L. Frese, A. Ksiazek, L Behr, J. Achermann, G. Stranzinger, J. Robert, B. Sanders, M. Sidler, C.E. Brokopp, S.T. Proulx, T. Frauenfelder, R. Schoenauer, M.Y.Emmert, V. Falk, S.P.Herstrup
BioTester2013Mechanical Analysis Of Ovine And Pediatric Pulmonary Artery For Heart Valve Stent DesignM.S. Cabrera, C.W.J. Oomens, C.V.C. Bouten, A.J.J.C. Bogers, S.P. Hoerstrup, F.P.T. Baaijens
BioTester2013Mechanics Of The Pulmonary Valve In The Aortic PositionA.L.F. Soares, D. van Geeman, A.J. van den Bogaerdt, C.W.J. Oomens, C.V.C. Bouten, F.P.T. Baaijens
BioTester2013Reduction Of Stromal Swelling Pressure After Uva-Riboflavin Cross-LinkingA.P. Sondergaard, A. Ivarsen, J. Hjortdal
BioTester2012A Murine Experimental Model For The Mechanical Behavior Of Viable Right-Ventricular MyocardiumD. Valdez-Jasso, M.A. Simon, H.C. Champion, M.S. Sacks
BioTester2012An Examination Of The Mechanical Properties Of The Annulus Fibrosus: The Effect Of Vibration On The Intra-Lamellar Matrix StrengthDiane Gregory, J. Callaghan
BioTester2012Application Of Simple Biomechanical And Biochemical Tests To Heart Valve Leaflets: Implications For Heart Valve Characterization And Tissue EngineeringH-Y. Huang, B.N. Balhouse, S. Huang
BioTester2012Biomechanical Properties Of The Transverse Carpal Ligament Under Biaxial StrainMichael Holmes, S. Howarth, J. Callaghan, P. Keir
BioTester2012Multi-Scale Mechanical Characterization Of Scaffolds For Heart Valve Tissue EngineeringG. Argento, M. Simonet, C.W.J. Oomens, F.P.T. Baaijens
BioTester2011A Comparison Of Uniaxial And Biaxial Mechanical Properties Of The Annulus Fibrosus: A Porcine ModelDiane Gregory, J. Callaghan
BioTester2011Does Vibration Influence The Initiation Of Intervertebral Disc HerniationDiane Gregory, J. Callaghan
BioTester2011Novel Lap Test Determines The Mechanics Of Delamination Between Annular Lamellae Of The Intervertebral DiscD. Gregory, J. Veldhuis, C. Horst, W. Brodland, J. Callaghan
BioTester2011Surfactant Assisted Incorporation Of Single-Walled Carbon Nanotubes Into A Chitosan-Polyvinylpyrrolidone PolymerT. Davis, J. Zhang, J.E. Herrera
BioTester2010An Examination Of The Influence Of Strain Rate On Subfailure Mechanical Properties Of The Annulus FibrosusD. Gregory, J. Callaghan
BioTester2010Biaxial Mechanical Testing Of Human ScleraA. Eilaghi, J. Flanagan, I. Tertinegg, C. Simmons, W. Brodland, R. Ethier
BioTester2010Effects Of Sclera Stiffness On Biomechanics Of The Optic Nerve Head In GlaucomaA. Eilaghi
BioTester2010Effects Of Sclera Stiffness Properties On Optic Nerve Head BiomechanicsA. Eilaghi, J. Flanagan, C. Simmons, R. Ethier
BioTester2009Fabrication Of Nanofiber Reinforced Protein Structures For Tissue EngineeringV. Beachley, X. Wen
BioTester2009Strain Uniformity In Biaxial Specimens Is Highly Sensitive To Attachment DetailsA. Eilaghi, J. Flanagan, G.W. Brodland, R. Ethier
BioTester2009The Influence Of The Tensile Material Properties Of Single Annulus Fibrosus Lamellae And The Interlamellar Matrix Strength On Disc Herniation And ProgressionD. Gregory

BioTester高分辨率雙軸薄膜拉伸測試分析系統(tǒng)介紹

系統(tǒng)概況: 
cellscale品牌BIOTESTER膜狀生物材料雙軸拉伸測試分析系統(tǒng),平面材料雙軸測試系統(tǒng) 
BioteSter膜狀生物材料雙軸拉伸測試分析系統(tǒng)(平面材料雙軸測試系統(tǒng))是一套簡單易用的對軟組織和生物材料進行定性研究的測試系統(tǒng),它可實時捕捉材料的動態(tài)圖像并同步顯示,分析力與位移以及同步視頻圖像用于分析結(jié)果和驗證,所得數(shù)據(jù)可輕松輸出為標準的電子表格,讓您的實驗結(jié)果一目了然!
BioteSter膜狀生物材料雙軸拉伸測試分析系統(tǒng)(平面材料雙軸測試系統(tǒng))是用于測試小的生物材料樣本的材料力學特性,并對測試的圖像和數(shù)據(jù)進行分析的完整系統(tǒng)。
BioteSter膜狀生物材料雙軸拉伸測試分析系統(tǒng)(平面材料雙軸測試系統(tǒng))能測試的生物材料包括:皮膚、韌帶、血管、心臟瓣膜、鞏膜、細胞膜、支架等及其替代組織。儀器緊湊、使用便捷,內(nèi)置強大的圖像跟蹤和分析軟件可以對數(shù)據(jù)、圖像和視頻進行同步處理。數(shù)據(jù)可以以電子表格的形式導出,或者導入到分析軟件中進行分析。
儀器特征: 
1. 快速、準確及可重復(fù)的樣本裝載;可以對平面組織進行單軸或雙軸拉力測量;
2. 測試樣本可以小到3X3毫米,大的可到15X15毫米;可以進行多模塊周期的、簡單的和松弛測試;
3. 實時的數(shù)據(jù)制圖、綜合圖像跟蹤包、測試期間的實時反饋及圖像分析軟件;用USB 接口快速地連接到帶有圖像和標記跟蹤軟件的控制計算機;
4. 直覺測試設(shè)計、集成的高分辨率CCD 相機可以為動態(tài)成像提供同步視頻跟蹤(高達15 幀/秒);
5. 緊湊型機械形狀系數(shù);

  • 4 個高精度力學加載裝置
  • 基于高精度CCD成像的應(yīng)變測量方式
  • 多種附件可供選擇,包括具有專li 技術(shù)的BioRakes——用于快速可靠的樣品安裝
  • 集成化的溫度控制池
  • 全功能用戶界面軟件,操作簡單,實時反饋循環(huán)、松弛以及多模態(tài)測試


儀器參數(shù):

cellscale品牌BIOTESTER膜狀生物材料雙軸拉伸測試分析系統(tǒng),平面材料雙軸測試系統(tǒng)

該系統(tǒng)小測試樣本為 3×3mm,移動分辨率達到微米級,專li的夾持系統(tǒng)有助于快速和精準的樣本固定,讓您的實驗更精準、更高效!您也可選擇針腳鉤子或直接夾住的固定系統(tǒng),多種測試模式可選,并提供控溫浴槽,滿足您不同的實驗需求。 
cellscale品牌BIOTESTER膜狀生物材料雙軸拉伸測試分析系統(tǒng),平面材料雙軸測試系統(tǒng) 
BioteSter膜狀生物材料雙軸拉伸測試分析系統(tǒng)(平面材料雙軸測試系統(tǒng))應(yīng)用領(lǐng)域非常廣泛,可用于生物組織、醫(yī)療器械、紡織品、橡膠材料、塑料薄膜、金屬、復(fù)合材料的研究,在生物醫(yī)學研究領(lǐng)域,主要用于人工皮膚、人造血管、人心臟瓣膜、人工角膜、人工鞏膜、人工肌腱、人工韌帶、人工軟組織、人工椎間盤、人工纖維環(huán)等,這些膜狀結(jié)構(gòu)中的膜材料在體內(nèi)均為雙向拉伸狀態(tài),因此傳統(tǒng)的單軸拉伸檢測試驗方法并不能如實反映材料在實際工程中的受力情況。
隨著新材料以及工業(yè)的發(fā)展,對于橡膠、塑料、紡織品、布匹、紙張、薄膜等高分子材料的各向同性或者各向異性需要深入研究和測試,因此平面材料雙軸拉伸測試系統(tǒng)也可以用于測量膜材強度、彈性模量等多種力學性質(zhì)。
cellscale品牌BIOTESTER膜狀生物材料雙軸拉伸測試分析系統(tǒng),平面材料雙軸測試系統(tǒng)
cellscale品牌BIOTESTER膜狀生物材料雙軸拉伸測試分析系統(tǒng),平面材料雙軸測試系統(tǒng)
cellscale品牌BIOTESTER膜狀生物材料雙軸拉伸測試分析系統(tǒng),平面材料雙軸測試系統(tǒng)
cellscale品牌BIOTESTER膜狀生物材料雙軸拉伸測試分析系統(tǒng),平面材料雙軸測試系統(tǒng)

 

 

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~

對比框

產(chǎn)品對比 產(chǎn)品對比 聯(lián)系電話 二維碼 意見反饋 在線交流

掃一掃訪問手機商鋪
86-010-67529703
在線留言