產(chǎn)品展廳收藏該商鋪

您好 登錄 注冊

當前位置:
世聯(lián)博研(北京)科技有限公司>>細胞培養(yǎng)監(jiān)測監(jiān)控分析系統(tǒng)>>96-square half deepwell microplate 300

96-square half deepwell microplate 300

返回列表頁
  • 96-square half deepwell microplate 300

收藏
舉報
參考價 面議
具體成交價以合同協(xié)議為準
  • 型號
  • 品牌 其他品牌
  • 廠商性質(zhì) 代理商
  • 所在地 北京市

在線詢價 收藏產(chǎn)品 加入對比 查看聯(lián)系電話

更新時間:2020-02-12 11:59:26瀏覽次數(shù):339

聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!

產(chǎn)品簡介

應(yīng)用領(lǐng)域 生物產(chǎn)業(yè)    
96-square half deepwell microplate 300
建議(默認)1∶25毫米振動篩振幅,300轉(zhuǎn)/分鐘(大腸桿菌培養(yǎng)NB,20倍減慢)0.25毫升0.3毫升0.35毫升(*混合至0.25毫升培養(yǎng)體積)

詳細介紹

96-square half deepwell microplate 300

96-square half deepwell microplate 300

96方半深孔微板孔內(nèi)流體力學(xué)

對于96平方的半深孔微量滴定板(CR1496c,專門用于培養(yǎng)目的),通常使用0.25-0.35毫升的培養(yǎng)體積,在50毫米振幅的振動篩上。振蕩頻率取決于培養(yǎng)液的體積,對于0.25或0.3ml的培養(yǎng)液,一般采用225或250轉(zhuǎn)/分,這種微孔板的氧傳遞速率(OTR)尚未測定。從96平方深井板(Duetz等人,2000,應(yīng)用和環(huán)境微生物學(xué)66:2641-2646)獲得的數(shù)據(jù)推斷,在225轉(zhuǎn)/分、40 mmol O2 l-1 h-1(對應(yīng)于200 h-1的kLa值)下,估計的OTR為250 ul。這樣的OTR對應(yīng)于在ErnMeYER振動篩燒瓶中的可實現(xiàn)(總瓶體積的培養(yǎng)體積10%,300轉(zhuǎn)/分),以確保*混合到底部(無死區(qū)),然而,建議使用250轉(zhuǎn)/分的振蕩頻率而不是225轉(zhuǎn)/分。在不使用高于0.25毫升的培養(yǎng)液的情況下(見本頁底部的兩個視頻蒸餾器。如果只有25毫米振幅的振動篩可用,則可以在培養(yǎng)液不接觸蓋子的情況下使用更高的振動頻率(275或300轉(zhuǎn)/分),還報告了在300轉(zhuǎn)/分(培養(yǎng)體積為0.25毫升)下?lián)u動以獲得良好的結(jié)果(流體力學(xué)和氧轉(zhuǎn)移速率與500毫米/225轉(zhuǎn)/分相當)

建議(默認)1∶25毫米振動篩振幅,300轉(zhuǎn)/分鐘(大腸桿菌培養(yǎng)NB,20倍減慢)0.25毫升0.3毫升0.35毫升(*混合至0.25毫升培養(yǎng)體積)

Hydrodynamics inside wells of a 96-square half deepwell microplate
For 96-square half deepwell microtiter plates (CR1496c, specifically designed for c*tion purposes), culture volumes between 0.25 ml and  0.35 ml are typically used, preferably on a shaker with a 50 mm amplitude. The optimal shaking frequency depends on the culture volume.For 0.25  or 0.3 ml cultures, 225 or 250 rpm is generally used.Oxygen transfer rates (OTR) for this kind of microplate have not been measured yet. Extrapolation from the data obtained with 96-square deepwell plates (Duetz et al., 2000, Applied and Environmental Microbiology 66:2641-2646) leads to an estimated OTR at 250 ul at 225 rpm of 40 mmol O2 l-1 h-1  (corresponding to kLa values of 200 h-1). Such an OTR corresponds to the high end achievable in Erlenmeyer shaker flasks (culture volume 10% of total flask volume, 300 rpm), To ensure full mixing down to the bottom (no dead zones), however, it may be advisable to use shaking frequencies of 250 rpm instead of 225 rpm. Even higher shaking frequencies (275 or 300 rpm) may be applied without the culture fluid touching upon the cover, on the condition that no higher culture volumes than 0.25 ml are used (see the bottom two video stills on this page.If only a shaker with a 25 mm amplitude is avaialble, shaking at 300 rpm (and a culture volume of 0.25 ml) is also reported to give good results (hydrodynamics and oxygen transfer rates comparable with 500 mm/225 rpm)
Adviced (default) condtion 1:25 mm shaker amplitude, 300 rpm(E. coli culture on NB, 20 times slowed down)    0.25 ml       0.3 ml      0.35 ml   (full mixing up to 0.25 ml culture volume)

 注:楊清辰發(fā)布

 

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~

對比框

產(chǎn)品對比 產(chǎn)品對比 聯(lián)系電話 二維碼 意見反饋 在線交流

掃一掃訪問手機商鋪
86-010-67529703
在線留言