Western blot protocol
Procedure for western blotting
Solutions and reagents:
Lysis buffers
These buffers may be stored at 4°C for several weeks or for up to a year aliquoted and stored at -20°C.
RIPA buffer (Sigma #R0278)
Complete Protease Inhibitor cocktail (Roche #)
PhosSTOP Phosphatase inhibitor Cocktail (Roche #)
1xTBS buffer
20 mM Tris-HCl
150 mM NaCl
Milli-Q Water
pH 7.5
1xTBST buffer
1xTBS buffer
0.1% (v/v) Tween-20
pH 7.5
Running Buffer
100 ml 10x Tris/Glycine/SDS (Bio-Rad #161-0732)
900 ml Milli-Q water
Transfer Buffer
100 ml 10x Tris/Glycine (Bio-Rad #161-0734)
200 ml methanol
700 ml Milli-Q water
Blocking buffer
5% (w/v) milk
Add to TBS buffer. Mix well.
Antibody dilution buffer
5% (w/v) milk
Add to TBST buffer. Mix well.
Procedure:
1. Sample lysis
Preparation of lysate from cell culture
1. Place the cell culture dish in ice and wash the cells with ice-cold PBS.
2. Aspirate the PBS, then add ice-cold lysis buffer (1 ml per 107 cells/100 mm dish/150 cm2 flask; 0.5ml per 5x106 cells / 60 mm dish / 75 cm2 flask).
3. Scrape adherent cells off the dish using a cold plastic cell scraper, then gently transfer the cell suspension into a pre-cooled microcentrifuge tube.
4. Maintain constant agitation for 30 minutes at 4°C.
5. Sonicate for 1 minutes (2 seconds working and 3 seconds rest for each cycle)
6. Spin at 16,000 x g for 20 minutes in a 4°C pre-cooled centrifuge.
7. Gently remove the tube from the centrifuge and place on ice. Transfer the supernatant to a fresh tube kept on ice, and discard the pellet.
2. Sample preparation
1. Determine the protein concentration for each cell lysate. (Appendix 1)
2. To the remaining volume of cell lysate, adjust the concentration of cell lysate at 1 ug/ul with lysis buffer, 4xSample Buffer (Invitrogen # NP0007) and 10xSample Reducing Agent (Invitrogen # NP0009).
3. To reduce and denature: Boil each cell lysate in sample buffer at 100°C for 5 minutes and aliquot. Store lysates at -20°C. Note: aliquot cell lysates (50- 100 μl) to avoid repeat freeze/thaw cycles.
4. Defrost tubes containing cell lysate at 37°C. Centrifuge at 16,000 x g in a microcentrifuge for 5 minutes.
3. Loading and running the gel
1. Load equal amounts of protein into the wells of the SDS-PAGE gel (Bio-Rad # 567-1085), along with molecular weight markers. Load 10- 40 μg of total protein from cell lysate.
2. Run the gel for 1 to 2 hours at 100 V.
4. Transferring the protein from the gel to the membrane
5. Antibody staining
1. Block the membrane for 1-2 hours at room temperature using 5% blocking solution.
2. Incubate membrane with appropriate dilutions of primary antibody (Appendix 2) in antibody dilution buffer overnight at 4°C.
3. Wash the membrane in three washes of 1xTBST, 5 minutes each.
4. Incubate the membrane with the recommended dilution of labeled secondary antibody in antibody dilution buffer at room temperature for 1 hour.
5. Wash the membrane in three washes of 1xTBST, 5 minutes each, then rinse in 1xTBS.
6. Scan the membrane according to the manual of Obyssey.
Appendix 1
Preparation of Standards and Working Reagent
A. Preparation of Diluted Albumin (BSA) Standards
Use Table 1 as a guide to prepare a set of protein standards. Dilute the contents of one Albumin Standard (BSA) ampule into several clean vials, preferably using the same diluent as the sample(s). Each 1mL ampule of 2mg/mL Albumin Standard is sufficient to prepare a set of diluted standards for either working range suggested in Table 1. There will be sufficient volume for three replications of each diluted standard. Table 1. Preparation of Diluted Albumin (BSA) Standards | |||
Dilution Scheme for Standard Test Tube Protocol and Microplate Procedure (Working Range = 20-2,000μg/mL) | |||
Vial | Volume of Diluent (μL) | Volume and Source of BSA (μL) | Final BSA Concentration (μg/mL) |
A | 0 | 300 of Stock | 2000 |
B | 125 | 375 of Stock | 1500 |
C | 325 | 325 of Stock | 1000 |
D | 175 | 175 of vial B dilution | 750 |
E | 325 | 325 of vial C dilution | 500 |
F | 325 | 325 of vial E dilution | 250 |
G | 325 | 325 of vial F dilution | 125 |
H | 400 | 100 of vial G dilution | 25 |
I | 400 | 0 | 0 = Blank |
B. Preparation of the BCA Working Reagent (WR)
1. Use the following formula to determine the total volume of WR required:
(# standards + # unknowns) × (# replicates) × (volume of WR per sample) = total volume WR required
Example: for the standard test-tube procedure with 3 unknowns and 2 replicates of each sample:
(9 standards + 3 unknowns) × (2 replicates) × (2mL) = 48mL WR required
Note: 2.0mL of the WR is required for each sample in the test-tube procedure, while only 200 μl of WR reagent is required for each sample in the microplate procedure.
2. Prepare WR by mixing 50 parts of BCA Reagent A with 1 part of BCA Reagent B (50:1, Reagent A:B). For the above example, combine 50mL of Reagent A with 1mL of Reagent B.
Note: When Reagent B is first added to Reagent A, turbidity is observed that quickly disappears upon mixing to yield a clear, green WR. Prepare sufficient volume of WR based on the number of samples to be assayed. The WR is stable for several days when stored in a closed container at room temperature (RT).
Microplate Procedure (Sample to WR ratio = 1:8)
1. Pipette 25μL of each standard or unknown sample replicate into a microplate well (working range = 20-2000μg/mL).
Note: If sample size is limited, 10μL of each unknown sample and standard can be used (sample to WR ratio = 1:20). However, the working range of the assay in this case will be limited to 125-2000μg/mL.
2. Add 200μL of the WR to each well and mix plate thoroughly on a plate shaker for 30 seconds.
3. Cover plate and incubate at 37°C for 30 minutes.
4. Cool plate to RT. Measure the absorbance at or near 562nm on a plate reader.