上海信裕生物科技有限公司
中級會員 | 第12年

15221858802

當(dāng)前位置:首頁   >>   資料下載   >>   上皮細胞粘附分子(EPCAM)檢測試劑盒

上皮細胞粘附分子(EPCAM)檢測試劑盒

時間:2015-5-11閱讀:888
分享:
  • 提供商

    上海信裕生物科技有限公司
  • 資料大小

    46KB
  • 資料圖片

    查看
  • 下載次數(shù)

    420次
  • 資料類型

    JPG 圖片
  • 瀏覽次數(shù)

    888次
點擊免費下載該資料

上皮細胞粘附分子(EPCAM)檢測試劑盒

適用生物 Homo sapiens (Human,人)
上皮細胞粘附分子(EPCAM)檢測試劑盒檢測范圍 31.25-2000pg/mL 靈敏度 13.9pg/mL
樣本類型 Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
實驗時長 4.5h 實驗方法 雙抗夾心法 上皮細胞粘附分子(EPCAM)檢測試劑盒規(guī)格 96T
ELISA Kit for Epithelial Cell Adhesion Molecule (EPCAM)
FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!

Organism species Homo sapiens (Human)
上皮細胞粘附分子(EPCAM)檢測試劑盒Sample type Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
Format 96-well strip plate
Assay length 4.5 hours
Detection range 31.25-2000pg/mL The standard curve concentrations used for the ELISA’s were 2000pg/mL, 1000pg/mL, 500pg/mL, 250pg/mL, 125pg/mL, 62.5pg/mL, 31.25pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 13.9pg/mL.

Specificity
This assay has high sensitivity and excellent specificity for detection of Epithelial Cell Adhesion Molecule (EPCAM).
No significant cross-reactivity or interference between Epithelial Cell Adhesion Molecule (EPCAM) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Epithelial Cell Adhesion Molecule (EPCAM) and the recovery rates were calculated by comparing the measured value to the expected amount of Epithelial Cell Adhesion Molecule (EPCAM) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-104 101
EDTA plasma(n=5) 79-104 91
heparin plasma(n=5) 79-90 86

Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Epithelial Cell Adhesion Molecule (EPCAM) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Epithelial Cell Adhesion Molecule (EPCAM) 上皮細胞粘附分子(EPCAM)檢測試劑盒were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Epithelial Cell Adhesion Molecule (EPCAM) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 84-101% 96-104% 85-102%
EDTA plasma(n=5) 92-101% 94-105% 83-90% 78-102%
heparin plasma(n=5) 93-102% 83-99% 79-97% 98-105%

Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air上皮細胞粘附分子(EPCAM)檢測試劑盒 humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B 1×120μL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100μL standard or sample to each well. Incubate 2 hours at 37oC;
3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37oC;
4. Aspirate and wash 3 times;
5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
6. Aspirate and wash 5 times;
7. Add 90μL Substrate Solution. Incubate 15-25 minutes at 37oC;
8. Add 50μL Stop Solution. Read at 450nm immediay.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Epithelial Cell Adhesion Molecule (EPCAM). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to上皮細胞粘附分子(EPCAM)檢測試劑盒 Epithelial Cell Adhesion Molecule (EPCAM). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Epithelial Cell Adhesion Molecule (EPCAM), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Epithelial Cell Adhesion Molecule (EPCAM) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
撥打電話
在線留言