東京計(jì)器TOKYO KEIKI Inc.液壓和工業(yè)產(chǎn)品/多路閥電磁換向閥- dg4v-5系列
東京計(jì)器TOKYO KEIKI Inc.電磁換向閥-dg4v-5系列選型說明
FEATURES
MODEL CODE(F3) | - | DG4V | - | 5 | - | 2 | A | (L) | - | M | - | P | L | - | T | - | 6 | - | 40 | - | (P10) | 1 | | 2 | | 3 | | 4 | 5 | 6 | | | | 7 | 8 | | 9 | | 10 | | 11 | | 12 |
|
1. | Fluid | | Omit | for mineral oil, water glycol | | F3: | phosphate ester | 2. | Wet armature directional valve | | 3. | Mounting, ISO4401-05 | 4. | Spool type | 5. | Spring set | | A: | spring offset A type (2 position, single sol.) | | B: | spring offset B type (2 position, single sol.) | | C: | spring centered (3 position, dual sol.) | | N: | no spring detent | 6. | Solenoid assembly direction | | Omit | for st'd (energized, P to B, A to T) | | L: | left hand assembly (energized, P to A, B to T) | 7. | Wiring connection | | P: | plug-in conduit box G1/2 (PF1/2) | | U: | DIN43650 connector | | KU: | lead wire (350mm, DC only) | 8. | Elec.accessories | | Omit | for no accessories (P) | | 1: | no accessories (U) | | L: | indicator lamp (AC st'd) | | 4: | surge suppressor | | 7L: | indicator lamp and surge suppressor (DC st'd) | | 9L: | ADC rectifier (quick deenergize) and indicator lamp | | 12L: | ADC rectifier (slow deenergize)and indicator lamp | 9. | Solenoid voltage | | T: | 100 V 50/60 Hz, 110 V 60 Hz | | OV: | 200 V 50/60 Hz, 220 V 60 Hz | | G: | DC12 V | | H: | DC24 V | | TR: | 100 V 50/60 Hz (ADC rectifier) | | VR: | 200 V 50/60 Hz (ADC rectifier) | 10. | T port allowable back pressure | | 6: | 15.7 MPa (AC sol.) | | 7: | 20.6 MPa (DC sol.) | 11. | Design no. | 12. | Port orifice (option) | | Omit | for no port orifice (st'd) |
|
SPECIFICATIONSModel | Max. Working Press. (MPa) | Max. Flow (L/min) | Tank Port Backpress. (MPa) | Max. Shift. Freq. (times/min.) | Mass (kg) | Single Sol. | Double Sol. | AC | DC | ADC | DG4V-5 | 31.5 | consult mfr. | 15.7 (AC) | 240 | 180 | 120 | AC | DC | AC | DC | 20.6 (DC) | 3.6 | 4.4 | 4.6 | 6.1 |
|
SOLENOID SPECIFICATIONSPower | Volt. Code | Volt. (V) | Freq. (Hz) | Start. Current (A) | Holding Current (A) | Power Consump. (W) | Power Volt. Fluct. (%) | Insul. Class | (AC) | T | 100 | 50 | 6.8 | 0.69 | - | +10, -15 | H type (180 ºC) | 60 | 5.9 | 0.49 | - | +20, -10 | 110 | 60 | 6.5 | 0.59 | - | +10, -15 | B | 110 | 50 | 6.2 | 0.63 | - | +10, -15 | 115 | 60 | 5.8 | 0.52 | - | +15, -10 | 120 | 60 | 6.0 | 0.54 | - | +10, -15 | OV | 200 | 50 | 3.4 | 0.35 | - | +10, -15 | 60 | 3.0 | 0.25 | - | +20, -10 | 220 | 60 | 3.3 | 0.30 | - | +10, -15 | D | 220 | 50 | 3.1 | 0.32 | - | +10, -15 | 230 | 60 | 2.9 | 0.26 | - | +15, -10 | 240 | 60 | 3.0 | 0.27 | - | +10, -15 | (DC) | G | 12 | - | - | 3.17 | 38 | ±10 | H type (180 ºC) | H | 24 | 1.58 | OJ | 48 | 0.79 | R | 100 | 0.38 | AC ->DC (rectified) (ADC) | TR | AC100V 50/60Hz ->DC90V(coil) | - | 0.42 | 38 | ±10 | H type (180 ºC) | VR | AC200V 50/60Hz ->DC180V(coil) | 0.21 | 38 |
|