您好, 歡迎來到化工儀器網(wǎng)! 登錄| 免費注冊| 產(chǎn)品展廳| 收藏商鋪|
當前位置:深圳欣博盛生物科技有限公司>>細胞培養(yǎng)>> QUANTI-Luc™
產(chǎn)品型號
品 牌Invivogen
廠商性質(zhì)代理商
所 在 地深圳市
更新時間:2022-01-28 15:44:40瀏覽次數(shù):1140次
聯(lián)系我時,請告知來自 化工儀器網(wǎng)供貨周期 | 現(xiàn)貨 | 規(guī)格 | 5 pouches (5 x 25ml) |
---|---|---|---|
貨號 | rep-qlc2 | 應用領域 | 生物產(chǎn)業(yè) |
主要用途 | 科研 |
QUANTI-Luc™ is a lyophilized assay reagent containing all the components required to quantitatively measure the activity of Lucia luciferase and other coelenterazine-utilizing luciferases.
QUANTI-Luc™ is optimized for use with Lucia luciferase reporter cell lines for fast and efficient real-time measurements directly from the cell culture media.
QUANTI-Luc™ contains the coelenterazine substrate for the luciferase reaction, which produces a light signal that is quantified using a luminometer and expressed as relative light units (RLU).
The signal produced correlates to the amount of luciferase protein expressed, indicating promoter activity in the reporter assay.
One step reagent: just add water to prepare the assay reagent.
Substrate stability: reconstituted substrate is stable for up to a month, allowing multiple application use.
For increased signal intensity and stability, InvivoGen has developed QUANTI-Luc™ Gold. QUANTI-Luc™ Gold has been optimized for high throughput screening (HTS) assays.
Ready to use: Just add water
Cost effective: One pouch is sufficient for 5 x 96 well plates
Practical: Working reagent is stable for at least one month
Use with Lucia luciferase:
Exceptional sensitivity and reproducibility
No cell lysis required
Rapid acquisition of results
QUANTI-Luc™ is provided as packs of individually sealed pouches.
rep-qlc1: 2 pouches of QUANTI-Luc™
rep-qlc2: 5 pouches of QUANTI-Luc™
Each pouch contains everything needed to prepare 25 ml of reagent allowing the preparation of 500 wells of a 96-well plate.
QUANTI-Luc™ is shipped at room temparature.
Store at -20°C up to 12 months.
After preparation, product is stable 1 week at 4°C and at least 1 month at -20°C.
Note: This product is photosensitive and should be protected from light.
1. Prepare QUANTI-Luc™ reagent by adding 25 ml water to the contents of one pouch.
2. Transfer samples, for instance 10 µl of media from cells containing the secreted luciferase to opaque 96-microwell plates suitable for your luminometer.
3. Set up the luminometer prior to addition of 50 µl QUANTI-Luc™ reagent to each well either manually or by automated injection.
Measure luminosity in endpoint mode when using Lucia luciferase or in kinetic mode depending on the coelenterazine-luciferase used.
如需購買或咨詢該產(chǎn)品技術(shù)問題,請聯(lián)系Invivogen一級代理商-欣博盛生物
請輸入賬號
請輸入密碼
請輸驗證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責,化工儀器網(wǎng)對此不承擔任何保證責任。
溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務必確認供應商資質(zhì)及產(chǎn)品質(zhì)量。