Mm-Wave power meter-高靈敏度毫米波功率計
  • Mm-Wave power meter-高靈敏度毫米波功率計
舉報

貨物所在地:上海上海市

更新時間:2024-09-19 21:00:05

瀏覽次數(shù):182

在線詢價收藏產(chǎn)品

( 聯(lián)系我們,請說明是在 化工儀器網(wǎng) 上看到的信息,謝謝?。?/p>

高靈敏度毫米波功率計Features
0.01-220 GHz operating frequency
High sensitivity
Up to 55 dB dynamic range (0.1uW-30mW)
Small measuring time (< 1 sec)
RS-232, GPIB interface
SCPI protocol

 

高靈敏度毫米波功率計Features 
  • 0.01-220 GHz operating frequency
  • High sensitivity
  • Up to 55 dB dynamic range (0.1uW-30mW)
  • Small measuring time (< 1 sec)
  • RS-232, GPIB interface
  • SCPI protocol
高靈敏度毫米波功率計Applications 
  • Recommended for use by Rohde & Schwarz
  • Measurements of power level of mm-wave signal
  • Test equipment
高靈敏度毫米波功率計Description

The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.

DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor.

Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research.

ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay.

Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse.

Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available.

Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels.

Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors.  Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time. 

 

DPM-XX Key Features and Specifications

- Display readings: milliWatts, microWatts or dBm

- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)

- Frequency Range: 10 MHz to 220 GHz

- Min. measured Power: 0.1 microWatt (depending on frequency band)

- Dynamic Measurement Range: 55dB max. (depending on frequency band)

- Frequency step: 10 MHz

- SCPI or ELVA’s command protocol

- RS-232, GPIB interface

- Calibration accuracy ±0.04 dB (log) or ±1%

- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory

- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness. 

Model NumberDPM-C DPM -28 DPM -22DPM -19DPM -15DPM -12DPM -10DPM -08DPM -06DPM -05
Frequency Band KaQUVEWFDG
Frequency Range, GHz0.01-26.51475733-5040-6050-7560-9075-11090-140110-170140-220
Input Waveguide/Impedance 50 Ohm, CoaxialWR-28WR-22WR-19WR-15WR-12WR-10WR-08WR-06WR-05
Wavequide Flange/ConnectorSMA, maleUG-599/UUG-383/UUG-383/U-M UG-385/U UG-387/UUG-387/U-MUG-387/U-MUG-387/U-MUG-387/U-M
Dynamic Range, dB (max)50555555555555555040
Min Measured Power Level, dBm-33-43-43-43-43-43-40-40-35-25
Measurement Rate (default), times per sec 2222222222
VSWR (power sensor)1.2:11.3:11.3:11.3:11.3:11.4:11.4:11.4:11.4:11.4:1

Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).

 

上海屹持光電技術有限公司