產(chǎn)地類別 | 進(jìn)口 |
---|
Ultra-sensitive universal refrigerant leak detector
?Detects all CFC, HFC and HCFC refrigerants as low as 0.006 oz/yr, including R-410a and R-507
?Dual power options allow battery operat
參考價(jià) | 面議 |
更新時(shí)間:2017-10-17 15:09:02瀏覽次數(shù):355
聯(lián)系我們時(shí)請(qǐng)說(shuō)明是化工儀器網(wǎng)上看到的信息,謝謝!
銷售:鐘
The H-10 PRO、The H-10 PRO、The H-10 PRO
The H-10 PRO is a highly responsive universal refrigerant leak detector using Bacharach’s tried-and-true heated diode sensor technology. It’s ultra-sensitive to all halogen-based, non-flammable CFC, HFC and HCFC refrigerants for reliable use in a wide range of refrigerant leak detection applications.
The H-10 PRO has a long probe (4.5 ft.) for detecting leaks in hard-to-reach areas, visual and audible indicators to show relative leak sizes and an auto-zeroing feature (automatic mode only) for finding leaks in backgrounds where target gas is present. It has an internal sensor calibration reference to ensure optimum performance and comes with a 3 year warranty.
Refrigerants Detected[1] | All CFC, HFC and HCFC refrigerants, including but not limited to: R-12, R-22, R-134a, R-404A, R-410A, R-502, R-507, HFO-1233zd, HFO-1234yf and HFO-1234ze |
Sensitivity[2] | 0.006 oz/yr (stationary) 0.1 oz/yr (moving per SAE J2791) |
Response Time | 1 second |
Leak Indicators | Visual (red LED in probe tip) and audible (via internal speaker or headphones) |
Automatic Background Adjustment | Yes, in automatic mode |
Power | 12 VDC internal rechargeable battery or via 100-240 VAC wall adapter/charger |
Run Time | 3 hours (typical) on fully-charged battery |
Size (H x W x D) | Unit: 8.3 x 10.5 x 5.4 in. (21.1 x 26.7 x 13.7 cm) Probe: 4.5 ft. (1.37 m) |
Weight | 5.1 lbs. (2.3 kg) |
Sensor Life[3] | 1 year (typical) |
Operating Conditions | 32 to 104 °F (0 to 40 °C), 10 to 90% RH (non-condensing), 1 ATM |
Warm-up Time | 2 minutes (approximate) |
Approvals | CE mark |
Warranty | Instrument - 3 Years Sensor, Battery - 1 Year Does not include probe, filters or leak bottle |
[1] DO NOT use this device to detect for leaks of refrigerants which are rated as combustible/flammable gases (e.g. ASHRAE A2- or A3- rated refrigerants).
[2] Sensitivity for R-12, R-22, R-124a, R-410A, R-404A and R-507 when unit is set to small leak setting, manual mode.
[3] Based on normal use. Consistent and/or constant exposure to high levels of refrigerant will deteriorate the sensor life more quickly. Increasing the sensor heater will also impact sensor life.