Dionex IonPac AS19-4μm 陰離子交換色譜柱
實現(xiàn)痕量鹵氧化物和無機陰離子的高分辨率分離飲用水使用Thermo Scientific Dionex IonPac AS19-4μm的氫氧化物選擇性陰離子交換柱。高分辨率、高容量和選擇性允許飲用水中溴酸鹽的測定在低μg/L水平。相比以往的Dionex IonPac AS19陰離子交換柱柱,這使用較小的樹脂顆粒更有效的分離導(dǎo)致更準(zhǔn)確的峰值積分和更可靠的結(jié)果。
Dionex IonPac AS19-4μm 陰離子交換色譜柱
訂貨信息:
Analytical Columns | |
Dionex IonPac AS19-4μm Analytical Column (4 × 250 mm) | 83217 |
Dionex IonPac AS19-4μm Analytical Column (2 × 250 mm) | 83223 |
Dionex IonPac AS19-4μm Capillary Column (0.4 × 250 mm) | 83230 |
Guard Columns | |
Dionex IonPac AG19-4μm Guard Column (4 × 50 mm) | 83221 |
Dionex IonPac AG19-4μm Guard Column (2 × 50 mm) | 83225 |
Dionex IonPac AG19-4μm Capillary Guard Column (0.4 × 50 mm) | 83233 |
Higher Resolution of Trace Oxyhalides and Inorganic Anions in Complex Matrices using Smaller Particle Columns
Achieve high resolution separations of trace oxyhalides and inorganic anions in drinking water using the Dionex IonPac AS19-4μm hydroxide-selective anion-exchange column. Its high resolution, high capacity and selectivity allow the determination of bromate in drinking water at the low-μg/L level. Compared to the previous Dionex IonPac AS19 column, the new anion-exchange column uses smaller resin particles for more efficient separations resulting in more accurate peak integration and more reliable results. It has similar selectivity and increased peak efficiencies compared to the Dionex IonPac AS19 column, ensuring that applications run on the Dionex IonPac AS19 can be easily transferred to the Dionex IonPac AS19-4μm column. The Dionex IonPac AS19-4μm columns meets the performance requirements of US EPA Methods 300.0 and 300.1.
The Dionex IonPac AS19-4μm column is available in three formats: 4 × 250 mm, 2 × 250 mm and 0.4 × 250 mm.The Dionex IonPac AS19-4μm Capillary Column is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column), but requires only 1/100th the eluent flow rate.The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs.
Recommended hydroxide-selective column for trace bromate in drinking water matrices
High capacity: 240 μeq per column (4 × 250 mm)
Meets or exceeds performance requirements of US EPA Methods 300.0 and 300.1
Column selectivity is optimized for 30 °C operating temperature
Compatible with organic solvents
High-pressure Thermo Scientific Dionex ICS-5000+ or Dionex ICS-4000 HPIC system is required to run at standard flow rates.
The Dionex IonPac AS19-4μm column is designed for the analysis of oxyhalides and common inorganic anions including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate in drinking water, groundwater, wastewater, and other diverse sample matrices. The Dionex IonPac AS19-4μm column allows analysis of most drinking water without the use of sample pretreatment or preconcentration. This column is ideally used with an RFIC system for automatic eluent generation.
The key application for the Dionex IonPac AS19-4μm column is the determination of trace bromate in drinking water matrices using a potassium hydroxide gradient with suppressed conductivity detection. The selectivity of the Dionex IonPac AS19-4μm column ensures that bromate can be quantified at low μg/L concentrations using suppressed conductivity detection even in the presence of very high concentrations of chloride, sulfate, and carbonate.
The smaller resin particles used in the Dionex IonPac AS19-4μm column produce a backpressure over 3000 psi at the standard flow rates. A high-pressure IC system, such as the Dionex ICS-5000+ HPIC or the Dionex ICS-4000 Capillary HPIC system is required.
Note: Use the Thermo Scientific Dionex AERS 500 Anion Electrolytically Regenerated Suppressor with the Dionex IonPac AS19-4μm column for eluent suppression.
Dionex IonPac AS19-4μm Anion-Exchange Column Specifications | |
---|---|
Dimensions | Dionex IonPac AS19-4μm Analytical Column: 2 × 250 mm and 4 × 250 mm Dionex IonPac AG19-4μm Guard Column: 2 × 50 mm and 4 × 50 mm Dionex IonPac AS19-4μm Capillary Column: 0.4 × 250 mm Dionex IonPac AG19-4μm Capillary Guard Column: 0.4 × 50 mm |
Maximum operating pressure | 5000 psi (standard and microbore) 5000 psi (capillary) |
Ion-exchange group | Functional Group: Alkanol quaternary ammonium ion |
Functional group characteristics | Ultralow hydrophobicity |
Capacity | 2.4 μeq (0.4 × 250 mm capillary column) 0.06 μeq* (0.4 × 50 mm capillary guard column) 60 μeq (2 × 250 mm analytical column) 1.5 μeq* (2 × 50 mm guard column) 240 μeq (4 × 250 mm analytical column) 6 μeq* (4 × 50 mm guard column) *Guards are packed with a low-capacity microporous resin. |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
Substrate characteristics | Bead Diameter and Pore Size: 4 μm (0.4 x 250, 2 × 250 and 4 × 250 mm); super macroporous resin (2000 ?) 11 μm (0.4 x 50, 2 × 50 and 4 × 50 mm); microporous resin (<1 ?) Cross-Linking (%DVB): 55% |
Mobile phase compatibility | pH 0–14; 0–100% HPLC solvents |