F220 Bleeder Overtemperature Shutdown放氣器過熱停機(jī)

Description:說明:The regenerated energy from the mechanism of the machine via the motor has exceeded the power capability of the bleeder resistor. 通過電機(jī)已超過泄放電阻器的功率能力。

 

By exceeding the maximum resistance energy, the drive will shutdown

according to the set error reaction.

超過最大阻力能量,驅(qū)動(dòng)器將關(guān)閉根據(jù)設(shè)定誤差反應(yīng)。

Thereby protecting the bleeder from temperature damage.

從而保護(hù)泄放器免受溫度損壞。

 

Cause:原因:

The reflected energy from the machines mechanism over the motor is

too large.電機(jī)上機(jī)器機(jī)構(gòu)的反射能量為太大了。

 

Remedy:處理措施:

With too much power ---> reduce the acceleration value

功率過大--->降低加速度值

With too much energy ---> reduce the velocity

能量太大--->降低速度

Check the drive installation.

檢查驅(qū)動(dòng)器的安裝情況。

May require installation of an additional bleeder module.

可能需要安裝額外的放氣模塊。

 

力士樂不常見故障代碼查詢:

F218故障,驅(qū)動(dòng)器過熱停機(jī)。 驅(qū)動(dòng)器放大器散熱片溫度過高,散熱片溫度超過50度,驅(qū)動(dòng)器就會(huì)自動(dòng)斷電,防止放大器損壞。

F219故障,電機(jī)/馬達(dá)過熱停機(jī)。電機(jī)的溫度超過160度,到了電機(jī)不可以承受的溫度,驅(qū)動(dòng)器會(huì)立即停止工作。

F22故障,制動(dòng)電阻器過載停機(jī)。從機(jī)械上檢查到在生能量超過制動(dòng)器所能承受的能力,所以驅(qū)動(dòng)器停機(jī)。

F226故障,驅(qū)動(dòng)器電源電源不穩(wěn)。伺服電機(jī)電壓值是有驅(qū)動(dòng)器控制,如果驅(qū)動(dòng)器電源電源電源下降到不足以給供給驅(qū)動(dòng)器的電壓,放大器就會(huì)停止工作。

F228故障,過大偏差。通過驅(qū)動(dòng)器監(jiān)控的數(shù)據(jù)檢測到模型的位置數(shù)值和實(shí)際反饋的數(shù)值不一樣,已經(jīng)超過了驅(qū)動(dòng)程序的最大值了。驅(qū)動(dòng)器停機(jī)工作。

 