賀德克HYDAC壓力繼電器成交孟加拉客戶(hù)
HYDAC壓力開(kāi)關(guān)EDS8446-2-0040-000的操作說(shuō)明
The EDS 8000 is an easy to set electronic pressure switch of compact design. Variants with one or two PNP transistor switch outputs are available. The setting of the switching points is accomplished using two pressure buttons and one four-character digital display. The switch position is signalled during operation by a green or red background illumination, respectively. For optimum adjustment to the respective application, the device offers a multitude of additional setting parameters, e.g. switching delay times, opener/closer functions for the outlets. The EDS 8000 is available in various pressure ranges between 0 ... 25 bar and 0 ... 600 bar. The main applications of the EDS 8000 are pressure and limit value messages in the areas of hydraulics and pneumatics or wherever a high switching frequency or a constant switching accuracy is more than mechanical pressure switches can provide.
Menu navigation in accordance with VDMA
1 or 2 PNP transistor switching outputs
Robust stainless steel measuring cell
Accuracy class ±1% FS max.
4-character digital display
Multi-colour switching display
Protection class IP 67
Simple handling through key programming
Many helpful additional functions
EN 61000-6-1 / 2/3/4
馬克2)證書(shū)號(hào):E318391
抗震動(dòng)
DIN EN 60068-2-6 ..在0500赫茲
約10g
耐沖擊性
DIN EN 60068-2-29(11毫秒)
約50g
根據(jù)IEC 60529 IP 67防護(hù)等級(jí)(使用一個(gè)IP 67
聯(lián)接器插座)
其他尺寸
電源電壓
按照UL說(shuō)明書(shū)中使用時(shí)
9.6 .. 32 V DC
- 有限的能量 - 根據(jù)
9.3 UL 61010;第2類(lèi); UL一千五百八十五分之一千三百一十;
LPS UL 60950
zui大電流消耗。共有0535
zui大。 35毫安非活動(dòng)開(kāi)關(guān)輸出
顯示:4位,LED,7段,
字符高度4.5毫米
壽命> 10億元。負(fù)載的變化(0 .. 100%)
重量:70克
FS(滿(mǎn)刻度)=相對(duì)于全量程
1)
-25℃下用FPM密封,-40°上請(qǐng)求℃。
2)
按照1.4.2 UL 61010-1環(huán)境條件; C22.2號(hào)61010-1
工作原理
HYDAC壓力繼電器有柱塞式、膜片式、彈簧管式和波紋管式四種結(jié)構(gòu)形式。下面對(duì)
柱塞式壓力繼電器賀德克HYDAC壓力繼電器成交孟加拉客戶(hù)
柱塞式壓力繼電器(見(jiàn)圖1)的工作原理作一介紹:
當(dāng)從繼電器下端進(jìn)油口3進(jìn)入的液體壓力達(dá)到調(diào)定壓力值時(shí),推動(dòng)柱塞2上移,此位移通過(guò)杠桿放大后推動(dòng)微動(dòng)開(kāi)關(guān)4動(dòng)作。改變彈簧1的壓縮量,可以調(diào)節(jié)繼電器的動(dòng)作壓力。
應(yīng)用場(chǎng)合:用于安全保護(hù)、控制執(zhí)行元件的順序動(dòng)作、用于泵的啟閉、用于泵的卸荷。
注意: 壓力繼電器必須放在壓力有明顯變化的地方才能輸出電信號(hào)。若將壓力繼電器放在回油路上,由于回油路直接接回油箱,壓力也沒(méi)有變化,所以壓力繼電器也不會(huì)工作
920856 EDS8446-1-0025-000
924314 EDS8446-1-0025-N00
920857 EDS8446-1-0040-000
920859 EDS8446-1-0100-000
920860 EDS8446-1-0250-000
924059 EDS8446-1-0250-N00
920563 EDS8446-1-0400-000
924694 EDS8446-1-0400-N00
920862 EDS8446-1-0600-000
920770 EDS8446-2-0025-000
920858 EDS8446-2-0040-000
920774 EDS8446-2-0100-000
920861 EDS8446-2-0250-000
926165 EDS8446-2-0250-N00
920794 EDS8446-2-0400-000
926499 EDS8446-2-0400-N00
920863 EDS8446-2-0600-000
壓力開(kāi)關(guān) 壓力繼電器:
EDS 344-2-040-000 EDS 344-3-600-000
EDS 345-1-006-000 EDS 348-5-250-000
EDS 1791-P-600-000 EDS 1791-N-400-000
ETS 4144-A-000 ETS 1701-100-000
ENS 3116-2-0410-000-K EVS 3100-1(006-060L/min)
植根于內(nèi)心的修養(yǎng),無(wú)需提醒的自覺(jué),以約束為前提自由,為他人著想的善良(企業(yè)文化)
走著走著,
醒了,
不再對(duì)所有人好,
誰(shuí)對(duì)我好我就對(duì)誰(shuí)好。
走著走著,
知道了,
日久不一定生情,
但一定能夠見(jiàn)人心。
首先用于安全保護(hù)時(shí),將壓力繼電器設(shè)置在夾緊液壓缸的一端
液壓泵啟動(dòng)后,首先將工件夾緊,此時(shí)夾緊液壓缸的右腔壓力升高,當(dāng)升高到壓力繼電器的調(diào)定值時(shí),壓力繼電器動(dòng)作,發(fā)出電信號(hào)使2YA通電,于是切削液壓缸進(jìn)刀切削。在加工期間,壓力繼電器微動(dòng)開(kāi)關(guān)的常開(kāi)觸點(diǎn)始終閉合。若工件沒(méi)有夾緊,壓力繼電器2斷開(kāi),于是2YA斷電,切削液壓缸立即停止進(jìn)刀,從而避免工件未夾緊被切削而出事故。
其實(shí)用于控制執(zhí)行元件的順序動(dòng)作時(shí),液壓泵啟動(dòng)后,首先2YA通電,液壓缸左腔進(jìn)油,推動(dòng)活塞方向右移。當(dāng)碰到限位器(或死擋鐵)后,系統(tǒng)壓力升高,壓力繼電器發(fā)出電信號(hào),使1YA通電,高壓油進(jìn)入液壓缸的左腔,推動(dòng)活塞右移。這時(shí)若3YA也通電,液壓缸的活塞快速右移;若3YA斷電,則液壓缸的活塞慢速右移,其慢速運(yùn)動(dòng)速度由節(jié)流閥調(diào)節(jié)。
再次用于液壓泵卸荷時(shí),壓力繼電器不是控制液壓泵停止轉(zhuǎn)動(dòng),而是控制二位二通電磁閥,將液壓泵5輸出的壓力油流回油箱,使其卸荷。
后用于液壓泵的啟閉時(shí),有兩個(gè)液壓泵,高壓小流量泵,低壓大流量泵。當(dāng)活塞快速下降時(shí),兩泵同時(shí)輸出壓力油。當(dāng)液壓缸活塞桿抵住工件開(kāi)始加壓時(shí),壓力繼電器在壓力油作用下發(fā)出動(dòng)作,觸動(dòng)微動(dòng)開(kāi)關(guān),將常閉觸點(diǎn)斷開(kāi),使液壓泵停轉(zhuǎn)。在加工過(guò)程中減慢液壓缸的速度,同時(shí)減少動(dòng)力消耗。
帶有測(cè)量值顯示
EDS 8000,符合VDMA的菜單導(dǎo)航,1或2個(gè)PNP晶體管開(kāi)關(guān)輸出,
4字符數(shù)字顯示,多色切換顯示,IP等級(jí)67
EDS 8000是一款設(shè)計(jì)緊湊、易于設(shè)置的電子壓力開(kāi)關(guān)。有一個(gè)或兩個(gè)PNP晶體管開(kāi)關(guān)輸出的變種。開(kāi)關(guān)點(diǎn)的設(shè)置是通過(guò)兩個(gè)壓力按鈕和一個(gè)四字符數(shù)字顯示器來(lái)完成的。開(kāi)關(guān)位置在操作過(guò)程中分別由綠色或紅色背景照明發(fā)出信號(hào)。為了對(duì)各自的應(yīng)用進(jìn)行調(diào)整,該設(shè)備提供了許多額外的設(shè)置參數(shù),例如開(kāi)關(guān)延遲時(shí)間、插座的開(kāi)啟/關(guān)閉功能。EDS 8000可以在0到0之間的各種壓力范圍內(nèi)使用。25巴和0…600巴。EDS 8000的主要應(yīng)用是液壓和氣動(dòng)領(lǐng)域的壓力和限值信息,或在高開(kāi)關(guān)頻率或恒定開(kāi)關(guān)精度高于機(jī)械壓力開(kāi)關(guān)的地方。
符合VDMA的菜單導(dǎo)航
1或2 PNP晶體管開(kāi)關(guān)輸出
堅(jiān)固的不銹鋼測(cè)量元件
精度等級(jí)大為±1%fs。
4字符數(shù)字顯示
多色切換顯示
防護(hù)等級(jí)IP 67
通過(guò)鍵編程簡(jiǎn)單處理
許多有用的附加功能
HYDAC壓力開(kāi)關(guān)EDS8446-2-0040-000的技術(shù)參數(shù)
量程范圍:-100Kpa~200MPa;
供電電壓:12~35V DC(24V DC 校準(zhǔn)電壓)/交流220vAC供電
輸出繼電器容量:380V 3A, 220V ,24V DC 等
精 度:優(yōu)于0.0.5%FS、1%FS等各種
設(shè)置范圍:全量程段可以設(shè)置
采樣速率:10次/秒(可以根據(jù)客戶(hù)需要定制要求的速度)。
接口螺紋:M20*1.5、G1/4、G1/2、1/4NPT(可以根據(jù)客戶(hù)需要定制)
使用注意事項(xiàng)
(1)根據(jù)具體用途和系統(tǒng)壓力選用適當(dāng)結(jié)構(gòu)形式的壓力繼電器,為了保證壓力繼電器動(dòng)作靈敏,避免低壓系統(tǒng)選用高壓壓力繼電器。
(2)應(yīng)按照制造廠(chǎng)的要求,正確安裝壓力繼電器。
(3)按照所要求的電源形式和具體要求對(duì)壓力繼電器中的微動(dòng)開(kāi)關(guān)進(jìn)行接線(xiàn)。
(4)壓力繼電器調(diào)整完畢后,應(yīng)鎖定或固定其位置.以免受振動(dòng)后變動(dòng)。
(5)壓力繼電器的泄油腔應(yīng)直接接回油箱,否則會(huì)使泄油口背壓過(guò)高,影響其靈敏度
壓力開(kāi)關(guān) 壓力繼電器:
EDS 344-2-040-000 EDS 344-3-600-000
EDS 345-1-006-000 EDS 348-5-250-000
EDS 1791-P-600-000 EDS 1791-N-400-000
ETS 4144-A-000 ETS 1701-100-000
ENS 3116-2-0410-000-K EVS 3100-1(006-060L/min)
正品德國(guó)賀德克HYDAC電子壓力開(kāi)關(guān)傳感器
帶測(cè)量值顯示
EDS 8000,菜單導(dǎo)航符合VDMA,1或2 PNP晶體管開(kāi)關(guān)輸出,
4字符數(shù)字顯示,多色開(kāi)關(guān)顯示,IP等級(jí)67
EDS 3000,可在縱軸和顯示器上旋轉(zhuǎn),4字符。LED顯示屏,以bar為單位顯示,psi
或MPA,每個(gè)按鈕可調(diào),取決于版本
-設(shè)計(jì)合規(guī)性
-帶前沖洗隔膜
技術(shù)
陶瓷隔膜上的厚層DMS(低壓范圍)
不銹鋼隔膜上的薄膜DMS(低壓和高壓范圍)
標(biāo)準(zhǔn)壓力范圍
在0…之間1和0…600/1000 bar相對(duì)壓力,取決于型號(hào)
高2.5巴壓力
調(diào)整也以psi和MPa為單位
其他壓力范圍和特殊調(diào)整也應(yīng)要求
電子壓力開(kāi)關(guān)
EDS 410
EDS 710
EDS 1700
EDS 300
EDS 3100
EDS 3300
EDS 3400
EDS 810
EDS 4400
EDS 8000
EDS 4100
EDS 4300
EDS 820
主要性能及選用標(biāo)準(zhǔn)
主要性能
HYDAC壓力繼電器的主要性能有以下幾個(gè)方面。
(1)調(diào)壓范圍
壓力繼電器能夠發(fā)出電信號(hào)的低工作壓力和高工作壓力的范圍稱(chēng)為調(diào)壓范圍。
(2)靈敏度與通斷調(diào)節(jié)區(qū)間
系統(tǒng)壓力升高到壓力繼電器的調(diào)定值時(shí),壓力繼電器動(dòng)作接通電信號(hào)的壓力稱(chēng)為開(kāi)啟壓力;系統(tǒng)壓力降低,壓力繼電器復(fù)位切斷電信號(hào)的壓力稱(chēng)為閉合壓力。開(kāi)啟壓力與閉合壓力的差值稱(chēng)為壓力繼電器的靈敏度。差值小則靈敏度高。為避免系統(tǒng)壓力波動(dòng)時(shí)壓力繼電器時(shí)通時(shí)斷,要求開(kāi)啟壓力與閉合壓力有一定的差值,此差值若可調(diào),則稱(chēng)為通斷調(diào)節(jié)區(qū)間。
(3)升壓或降壓動(dòng)作時(shí)間
壓力繼電器入口側(cè)壓力由卸荷壓力升至調(diào)定壓力時(shí),微動(dòng)開(kāi)關(guān)觸點(diǎn)接通發(fā)出電信號(hào)的時(shí)間稱(chēng)為升壓動(dòng)作時(shí)間,反之,壓力下降,觸點(diǎn)斷開(kāi)發(fā)出斷電信號(hào)的時(shí)間稱(chēng)為降壓動(dòng)作時(shí)間。
(4)重復(fù)精度
在一定的調(diào)定壓力下,多次升壓(或降壓)過(guò)程中,開(kāi)啟壓力或閉合壓力本身的差值稱(chēng)為重復(fù)精度,差值小則重復(fù)精度高。
選用標(biāo)準(zhǔn)
根據(jù)所測(cè)對(duì)象的壓力來(lái)選用,比如所測(cè)壓力范圍在8KG以?xún)?nèi),那么就要選用額定10KG的壓力繼電器,還有要符合電路中的額定電壓,接口管徑的大小。