自然基因科技有限公司

多肽合成儀,熒光原位雜交,耶拿攝像頭,微核分析

化工儀器網收藏該商鋪

18

聯系電話

13701376913

     小標 您所在位置:首頁 > 供求商機> LEJA計數板 100微米2腔-100 MICRON - 2 CHAMBER
產品搜索

請輸入產品關鍵字:

聯系方式
地址:北京海淀區(qū)芙蓉里南街6號白環(huán)公寓1905室
郵編:100080
聯系人:馬強
電話:010-51650520
傳真:010-51650521
手機:13701376913
留言:發(fā)送留言
網址:www.naturegene.cn
商鋪:http://true-witness.com/st94165/
供求商機

LEJA計數板 100微米2腔-100 MICRON - 2 CHAMBER

  • 發(fā)布日期:
  • 有效日期:
  • 所 在 地:
  • 產  地:
  • 已獲點擊:

  • 2024年10月11日
  • 2025年4月11日
  • 美國自然基因有限公司(Natu
  • 126次

【產品簡介】

100 MICRON - 2 CHAMBER


【詳細說明】

100 MICRON - 2 CHAMBER. A number is not always what it seems to be. What is the confidence interval? How accurate and how precise is your counting method? The Leja 100 micron slide has two purposes. First, it can be used to determine azoospermia, and secondly it can be used to perform a post-vasectomy check. Accuracy is extremely important, this Leja slide gives you accuracy, precision, and speed!
100 MICRON - 2 CHAMBER的詳細介紹

100 MICRON - 2 CHAMBER.

A number is not always what it seems to be. What is the confidence interval? How accurate and how precise is your counting method? The Leja 100 micron slide has two purposes. First, it can be used to determine azoospermia, and secondly it can be used to perform a post-vasectomy check. Accuracy is extremely important, this Leja slide gives you accuracy, precision, and speed!

DETERMINATION OF AZOOSPERMIA
Statistically speaking it is impossible to assess a concentration of zero. Therefore it seems impossible to determine azoospermia, since by definition there are no sperms. Due to the large, fixed volume of the chamber, the Leja method for determining azoospermia is the most accurate and reliable method to determine azoospermia and very low sperm count (0- 20,000/ml). The Leja 100 micron slide is the best way of getting a statistical meaningful result combined with speed.

POST-VASECTOMY CHECK
The Leja 100 micron chamber is more accurate than other manufactured chambers concerning the lowest level of detection and the lowest level of quantification (lowest limit of detection Makler: 100,000/ml. Leja: 40/ml; lowest limit of quantification Makler: 2,500,000/ml, Leja: 1,000/ml).

Reliable Post-vasectomy checks are very important. Besides the fact that the patient wants to be sure the operation was successful, the doctor needs to be sure of the results in order to avoid liability claims. The benefits of wroking with the Leja 100 micron slide are that you will save a lot of time. No spinning down is needed anymore, so no samples will be rejected to a high white blood cell count. The average number of analysis needed before clearance might go down up to a factor 2!

Please download a PDF brochure here [437 KB].
Catalogue number: SC-100-01-02-A

    
留言框
感興趣的產品: *
留言內容:
您的姓名: *
您的單位:
聯系電話: *
微信:
常用郵箱:
詳細地址:
省份: *
驗證碼: * =   請輸入計算結果(填寫阿拉伯數字),如:三加四=7
      
| 商鋪首頁 | 公司檔案 | 產品展示 | 供應信息 | 公司動態(tài) | 詢價留言 | 聯系我們 | 會員管理 |
化工儀器網 設計制作,未經允許翻錄必究.Copyright(C) http://true-witness.com, All rights reserved.
以上信息由企業(yè)自行提供,信息內容的真實性、準確性和合法性由相關企業(yè)負責,化工儀器網對此不承擔任何保證責任。
溫馨提示:為規(guī)避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。
二維碼

掃一掃訪問手機站