| 注冊| 產(chǎn)品展廳| 收藏該商鋪

行業(yè)產(chǎn)品

當(dāng)前位置:
廣州尖分科學(xué)儀器有限公司>>戴安 Dionex>>Bio Columns>> GlycanPac AXR-1 Glycan Analysis Column

GlycanPac AXR-1 Glycan Analysis Column

返回列表頁
  • GlycanPac AXR-1 Glycan Analysis Column
收藏
舉報
參考價 面議
具體成交價以合同協(xié)議為準
  • 型號
  • 品牌
  • 廠商性質(zhì) 代理商
  • 所在地 廣州市
在線詢價 收藏產(chǎn)品

更新時間:2016-10-27 16:15:47瀏覽次數(shù):714

聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!

同類優(yōu)質(zhì)產(chǎn)品

更多產(chǎn)品

產(chǎn)品分類品牌分類

更多分類

產(chǎn)品簡介

GlycanPac AXR-1 Glycan Analysis ColumnGlycanPac AXR-1 Columns for the High-Resolution Separation and Analysis of Glycans

詳細介紹

lycanPac AXR-1 Columns for the High-Resolution Separation and Analysis of Glycans

The Thermo Scientific GlycanPac AXR-1 column is a high-performance, silica-based HPLC column for the simultaneous separation of glycans by charge, isomerism, and size. It is designed to provide industry-leading resolution with unique selectivities for biologically important glycans, either labeled or native, using either fluorescence and/or mass spectrometry (MS) detection.

Features:

• Unique glycan selectivity based on charge, branch/linkage isomerism, and size
• Exceptional resolution for either native or derivatized glycans
• Utility for both high-resolution glycan structural characterization and glycan quantification
• Compatibility with both MS and fluorescence detection methods
• Reliable column performance
• Available in HPLC (3 µm) and UHPLC (1.9 µm) formats.

The GlycanPac AXR-1 column, based on innovative, mixed-mode surface chemistry, combines both weak anion-exchange (WAX) and reversed-phase interaction mechanisms to produce exceptional glycan selectivity and industry-leading resolution. The WAX functionality provides retention of negatively charged glycans that elute in order of increasing charge, and the reversed-phase mode facilitates resolution of glycans of the same charge according to their isomerism and size. These attributes produce unparalleled glycan separations. The GlycanPac AXR-1 column is designed for HPLC and UHPLC methods using either fluorescence or MS detection, and uses volatile aqueous buffers (e.g., ammonium acetate or ammonium formate) and acetonitrile, presenting the eluting glycans ready for introduction into MS instruments.

GlycanPac AXR-1 columns are based on high-purity and spherical silica substrates in both 1.9 and 3 µm sizes for UHPLC and standard HPLC applications, respectively. GlycanPac AXR-1 columns are available in various dimensions for applications with different resolutions, throughput, and instrument requirements.

GlycanPac AXR-1 Column Specifications
Column Dimensions

1.9 μm: 2.1 × 250mm, 2.1 × 150mm

3 μm: 4.6 × 150mm, 3.0 × 150mm, 2.1 × 150mm

Particle SizeSpherical 1.9 μm, 3 μm particles
SubstrateHigh-purity, Porous, Spherical Silica
Surface Area220 m2/g
Pore size175 Å
Functional GroupWAX and RP Mixed-Mode
Recommended Flow Rate Range:

1.9 μm: 0.2 to 0.4 mL/min. for: all 2.1 mm columns

3 μm: 0.8 to 1.2 ml/min for 4.6 × 150 mm

          0.3 to 0.6 ml/min for 3.0 × 150 mm

          0.1 to 0.3 ml/min. for 2.1 × 150 mm

Pressure Limit

1.9 μm: 10,000 psi for 2.1 ×150mm

             15,000 psi for 2.1 × 250mm

3 μm: 6,000 psi for all 3 μm columns

Temperature Range:Ambient to < 60  ºC
pH Range2.0 - 8.0
 