上海境宣實(shí)業(yè)有限公司
中級會員 | 第17年

17601355022

當(dāng)前位置:上海境宣實(shí)業(yè)有限公司>>日本光明北川式氣體檢測管>>氣體快速檢測管>> 105SD戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm

戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm

參  考  價面議
具體成交價以合同協(xié)議為準(zhǔn)

產(chǎn)品型號105SD

品       牌

廠商性質(zhì)代理商

所  在  地上海市

更新時間:2025-01-15 21:38:31瀏覽次數(shù):1554次

聯(lián)系我時,請告知來自 化工儀器網(wǎng)
戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm,通過直接讀取方式,可簡單測定空氣中各種氣體的濃度。使用1個檢測器(泵),只要更換檢測管,就能進(jìn)行測定。由于是直接讀取式,所以不會出現(xiàn)人為誤差。1沖程(100ml)30~120秒,就可以結(jié)束濃度測定。

戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm

Tube 05SD
1. PERFORMANCE
1) Measuring range :1-20 ppm 0.2-1 ppm
Number of pump strokes 1(100ml) 5(500ml)
2) Sampling time :1 minute/1 pump stroke
3) Detectable limit :0.1 ppm(100ml)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Reading :Direct reading from the scale calibrated by 1 pump stroke
7) Colour change :Pale purple→Pale Yellow
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTION
By reacting with Phosphoric acid, PH indicator is discoloured.
2NH3+H3PO4→(NH4)2PO4
4. CALIBRATION OF THE TUBE
PERMEATION TUBE METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
20
18
16
14
12
10
8
6
4
2 1
100ml
ppm
GAS To pump
DEHUMIDIFIER
(White)
105SD AMMONIA
Substance Interference Coexistence
Amines Similar stain is produced. Higher readings are given.
(NOTE)
When the concentration is below 1 ppm, 2 to 5 pump strokes can be used to detemine the lower concentration.
Following formula is available for actual concentration.
Actual concentration=Reading value× 1
Number of strokes

The KITAGAWA Gas Detector Tube System is a complete sampling and analysis system for determining hazardous gas and vapour concentrations quickly and easily. The KITAGAWA Gas Detector Tube System is comprised of an Air Sampling Pump and Precision Gas Detector Tubes.

The KITAGAWA air sampling pump reproducibly draws 100cc of sample air through the detector tube. All detector tubes are calibrated for a single pump stroke; there is no need for multiple volumes or stroke counters.

Each detector tube is formulated with high purity reagents that absorb and react with the target gas or vapour being measured. A colorimetric stain is created that is proportional in length to the concentration. For most tubes, the concentration is read directly off the measurement scale on each tube. 
 How To Use The KITAGAWA Gas Detector Tube System 
 
Detector tubes are available to measure more than 200 different kinds of gases and vapours. For many gases and vapours, there are several concentration ranges available giving you the flexibility to measure both low and high concentrations without sacrificing precision.

For specific information, please refer to the list of detector tubes.

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
撥打電話