上海力孚同科技有限公司
中級會員 | 第2年

13671818969

當(dāng)前位置:上海力孚同科技有限公司>>Oximeter device testing>>PPG-2R-880 / PPG-2R-940 Reflectance SpO2 Module>> PPG-2R-880 / PPG-2R-940 Reflectance SpO2 Module

PPG-2R-880 / PPG-2R-940 Reflectance SpO2 Module

參   考   價: 1000

訂  貨  量: ≥1 件

具體成交價以合同協(xié)議為準(zhǔn)

產(chǎn)品型號

品       牌其他品牌

廠商性質(zhì)代理商

所  在  地上海市

更新時間:2024-09-26 08:37:20瀏覽次數(shù):366次

聯(lián)系我時,請告知來自 化工儀器網(wǎng)
同類優(yōu)質(zhì)產(chǎn)品更多>
應(yīng)用領(lǐng)域 醫(yī)療衛(wèi)生,生物產(chǎn)業(yè),電子,航天,綜合
PPG-2R-880 / PPG-2R-940 Reflectance SpO2 Module, The PPG-2R-880/PPG-2R-940 works with the AECG100 main console or SECG 5.0 AIO Multi Vital Sign Simulator, as the first reflectance SpO2 performance.

The PPG-2R-880/PPG-2R-940 Reflectance SpO2 Module,


works with the AECG100 main console or SECG 5.0 AIO Multi Vital Sign Simulator, as the first reflectance SpO2 performance tester designed for R&D in manufacturers. This dual-channel optical module outputs R and IR analog signals to test blood oxygen saturation (SpO2) and heart rate functions. Besides, it also allows users to individually adjust the R/IR’s rate of change of respiratory signals in PPG and set up add-on noise. It’s suitable for the development and verification of reflectance PPG products such as wearable devices to test performance.

OVERVIEW

Works with the AECG100 main console or SECG 5.0 AIO Multi Vital Sign Simulator to test heart rate, ECG, PPG, PWTT, and SpO2 functions

Outputs R and IR analog signals to simulate SpO2 signals

Adjustable SpO2 parameters, such as AC, DC, and PI values of R/IR, to confirm the accuracy of the SpO2 function

ECG function with adjustable PWTT parameters to verify the accuracy of blood pressure measurement algorithms

Respiratory variation simulation – add-on signals for more authentic testing

Equipped with Auto Sequence function – sorts the parameters of different test items into a designated order for automated testing while eliminating the need to develop automated testing programs

Raw data playback – plays recorded raw data or customized waveforms for repeated verification to facilitate the development process

Provides SDK supporting multiplatform for users to flexibly develop automated testing programs

Equipped with RCA to BNC ports to connect to an oscilloscope – outputs amplified and stable signals for viewing the voltage of AC analog signals of R/IR, optical signals received by the PPG-2R-880/PPG-2R-940, and the switch status of R/IR LED of DUT

Adjustable PPG waveform characteristic points, such as the Systolic Peak (SP), Dicrotic Notch (DN), and Diastolic Peak (DP), in a wide range and precise values for flexible test settings*

Allows users to configure noise with adjustable frequencies and amplitudes to output with PPG signals for testing*

*Note: Only available when paired with the AECG100.

Testing Scenario

PPG-2R-880 / PPG-2R-940 Reflectance SpO2 Module

The PPG-2R-880/PPG-2R-940 Reflectance SpO2 Module






會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
撥打電話
在線留言