文獻(xiàn)名:Understanding Membrane Fouling in Electrically Driven Energy Conversion Devices. Energies 2021, 14, 212

 

 

作者 Soo-Jin Han and Jin-Soo Park

Department of Green Chemical Engineering, College of Engineering, Sangmyung University,Cheonan 31066, Korea

 

摘要:Positively charged (cetylpyridinium chloride), negatively charged (sodium dodecyl sulfate), and non-charged (polyethylene glycol) surfactants are used as potential foulant in reverse electrodialysis systems supplying seawater and river freshwater. Fouling tendency of the foulants to ion-exchange membranes is investigated in terms of the adsorption by electromigration, electrostatic attraction, and macromolecule interaction in reverse electrodialysis systems. According to theoretical prediction of fouling tendency, charged foulants in seawater streams could foul ion-exchange membranes significantly. However, the worst fouling behavior is observed when the charged foulants are present in river streams. As a result of zeta potential measurement, it is found that the Debye length of the charged foulants decreases due to the higher ionic strength of seawater streams and causes to lower net electrostatic effect. It finally results in less fouling tendency in reverse electrodialysis.

 

關(guān)鍵詞:reverse electrodialysis; fouling; ion-exchange membrane; energy conversion device